Deformable gas-filled microbubbles targeted to P-selectin.

نویسندگان

  • Joshua J Rychak
  • Jonathan R Lindner
  • Klaus Ley
  • Alexander L Klibanov
چکیده

Ultrasound contrast microbubbles have been successfully targeted to a number of intravascular disease markers. We hypothesized that targeted delivery could be improved further, by making the microbubbles deformable, leading to increased microbubble-endothelium adhesion contact area and stabilized adhesion. Activated leukocytes utilize such strategy; they deform after binding to inflamed endothelium in the vasculature. Lipid-shell microbubbles were targeted to the endothelial inflammatory protein P-selectin with a monoclonal anti-P-selectin antibody attached to the microbubble shell. Deformable microbubbles were created by controlled pressurization with partial gas loss, which generated an average excess shell surface area of approximately 30% and the formation of outward-projected wrinkles and folds. Targeted microbubble adhesion and deformability were assessed in the parallel plate flow chamber under shear flow. Sustained adhesion of deformable microbubbles at wall shear stresses between 0.4 and 1.35 dyn/cm(2) was consistently better than adhesion of wrinkle-free microbubbles. Over this shear range, targeted wrinkled microbubbles were deformed by shear flow, unlike wrinkle-free microbubbles. In a murine cremaster inflammation model, a significant improvement of deformable microbubble targeting was observed by intravital microscopy. Overall, the mechanical aspects of adhesion, such as particle shape, deformability and surface microstructure, are important in engineering efficient site-targeted particle-based agents for medical imaging and therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Targeted ultrasound contrast agent for molecular imaging of inflammation in high-shear flow.

Targeted ultrasound contrast materials (gas-filled microbubbles carrying ligands to endothelial selectins or integrins) have been investigated as potential molecular imaging agents. Such microbubbles normally exhibit good targeting capability at the slower flow conditions. However, in the conditions of vigorous flow, binding may be limited. Here, we describe a microbubble capable of efficient b...

متن کامل

Dual targeting improves microbubble contrast agent adhesion to VCAM-1 and P-selectin under flow.

To improve ultrasound contrast agents targeted to the adhesion molecules P-selectin and VCAM-1 for the purpose of molecular imaging of atherosclerotic plaques, perfluorocarbon-filled phospholipid microbubble contrast agents were coupled by a polyethylene glycol-biotin-streptavidin bridge with mAb MVCAM.A(429), a sialyl Lewis(x) polymer (PAA-sLe(x)), or both (dual). Approximately three hundred t...

متن کامل

Ultrasound assessment of inflammation and renal tissue injury with microbubbles targeted to P-selectin.

BACKGROUND Routine methods capable of assessing tissue inflammation noninvasively are currently not available. We hypothesized that tissue retention of microbubbles targeted to the endothelial cell adhesion molecule P-selectin would provide a means to assess inflammation with ultrasound imaging. METHODS AND RESULTS Phospholipid microbubbles targeted to P-selectin (MB(p)) were created by conju...

متن کامل

Binding and detachment dynamics of microbubbles targeted to P-selectin under controlled shear flow.

This study was performed to assess the binding kinetics of a targeted microbubble contrast agent exposed to shear stress. An ultrasound contrast targeted to P-selectin was designed by conjugating monoclonal antibodies against murine P-selectin (RB40.34) to the lipid monolayer shell of the microbubble using poly(ethylene glycol)-biotin-streptavidin. The attachment and detachment of targeted micr...

متن کامل

Molecular Contrast-Enhanced Ultrasound Imaging of Radiation-Induced P-Selectin Expression in Healthy Mice Colon.

PURPOSE To evaluate the feasibility of using molecular contrast-enhanced ultrasound (mCEUS) to image radiation (XRT)-induced expression of cell adhesion molecules that mediate inflammatory response to XRT in healthy mouse colon tissue. METHODS AND MATERIALS The colons of male BALB/c mice (aged 6-8 weeks, n=9) were irradiated with 14 Gy using a Kimtron IC-225 x-ray irradiator operating at 225 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of controlled release : official journal of the Controlled Release Society

دوره 114 3  شماره 

صفحات  -

تاریخ انتشار 2006