Navigator gated high temporal resolution tissue phase mapping of myocardial motion.

نویسندگان

  • Bernd Jung
  • Maxim Zaitsev
  • Jürgen Hennig
  • Michael Markl
چکیده

Data acquisition for phase contrast velocity mapping of myocardial motion is typically based on multiple breath-held 2D measurements with limited acquisition duration and consequently relatively poor temporal resolution. In order to overcome the limitations of breath-hold acquisitions, an improved navigator-guided technique was implemented based on 2 navigator signals within each cardiac cycle in combination with paired acceptance and rejection criteria of successive navigator signals. Respiratory gated phase contrast measurements with 3-directional velocity encoding were performed in 12 healthy volunteers in basal, midventricular, and apical locations of the left ventricle during free breathing with a temporal resolution of 13.8 ms. Results were compared to standard breath-hold measurements with a temporal resolution of 69 ms. Data from the high temporal resolution study revealed details in left ventricular motion patterns that were previously not seen in phase contrast measurements and are only known from echocardiography. The proposed navigator gated technique for high temporal resolution velocity mapping is, therefore, highly promising for the detection of local and global motion abnormalities in patients with disturbed left ventricular performance, such as diastolic dysfunction.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of myocardial motion in children and young adults using High-temporal resolution MR tissue phase mapping

Background MR Tissue phase mapping (TPM) is a non-invasive tool to detect regional and global myocardial wall motion. Evaluation of myocardial velocity in radial and longitudinal direction throughout the cardiac cycle may help us better understand myocardial mechanics. Our goal is to investigate regional and global left ventricular myocardial motion using respiratory-gated high temporal resolut...

متن کامل

High resolution spiral myocardial phase velocity mapping (PVM) of the entire cardiac cycle

Background Three-directional PVM is capable of measuring regional myocardial velocities. Current techniques use Cartesian k-space coverage, and navigator-gated high spatial and temporal resolution acquisitions are long [1,2]. In addition, they use prospective ECG-gating and analysis of the full cardiac cycle is not possible. The aim of this study is to develop a high temporal and spatial resolu...

متن کامل

Efficient and reproducible high resolution spiral myocardial phase velocity mapping of the entire cardiac cycle

BACKGROUND Three-directional phase velocity mapping (PVM) is capable of measuring longitudinal, radial and circumferential regional myocardial velocities. Current techniques use Cartesian k-space coverage and navigator-gated high spatial and high temporal resolution acquisitions are long. In addition, prospective ECG-gating means that analysis of the full cardiac cycle is not possible. The aim ...

متن کامل

Detailed analysis of myocardial motion in volunteers and patients using high-temporal-resolution MR tissue phase mapping.

PURPOSE To detect and investigate details in left ventricular (LV) motion patterns with a temporal resolution comparable to that of echocardiography. MATERIAL AND METHODS To assess global and regional myocardial motion in high temporal detail, respiratory-gated MR phase-contrast measurements with three-directional velocity encoding (venc) were performed in 12 healthy volunteers and two patien...

متن کامل

Quantifying right ventricular motion and strain using 3D cine DENSE MRI

Background The RV is difficult to image because of its thin wall, asymmetric geometry and complex motion. DENSE is a quantitative MRI technique for measuring myocardial displacement and strain at high spatial and temporal resolutions [1,2]. DENSE encodes tissue displacement directly into the image phase, allowing for the direct extraction of motion data at a pixel resolution. A free-breathing n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 55 4  شماره 

صفحات  -

تاریخ انتشار 2006