Development of a Compact XAFS Measurement Chamber under Atmospheric Pressure in the Soft X-ray Region

نویسندگان

  • Koji Nakanishi
  • Toshiaki Ohta
چکیده

We have developed a compact experimental set-up for X-ray absorption fine structure (XAFS) measurements in He gas under atmospheric pressure (AP) in the soft X-ray region and used it for Mg and Cl K-edge XAFS measurements of MgCl2 and MgCl2・6H2O. The spectra of MgCl2・6H2O measured in He under AP were significantly different from those measured in vacuum. This suggests the importance of performing soft X-ray XAFS experiments under AP to obtain reliable spectra from hydrated compounds. The SR Center, Ritsumeikan University, Kusatsu, Shiga 525-8577

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

XAFS Measurement System in the Soft X-Ray Region for Various Sample Conditions and Multipurpose Measurements

An X-ray absorption fine structure (XAFS) spectroscopy is a powerful and useful technique to probe the local electronic structure and the local atomic structure around an absorbing atom in an unknown material [Stöhr, 1996, Ohta, 2002]. A highly bright X-ray source, synchrotron radiation (SR) is usually used for XAFS measurements to obtain reliable spectra, even for elements of very low content ...

متن کامل

استفاده از شتابگر الکترونی MeV 10 برای تولید تابش چرنکوف درناحیه پرتوایکس نرم

Cherenkov radiation is generated when relativistic charged particles move in a medium with refractive index larger than unity. Although, the refractive index is generally smaller than unity in X-ray region, in the vicinity of atomic absorption edges, the refractive index may exceed unity and Cherenkov radiation can be generated in soft X-ray region with a narrow band width. In this paper, the s...

متن کامل

Partial Fluorescence Yield XAFS Measurements in Soft X-ray Region Using a Large-Area Silicon Drift Detector

X-ray absorption fine structure (XAFS) spectra in the soft X-ray region are obtained in the electron and fluorescence yield modes, which are sensitive to surface and bulk, respectively. A micro-channel plate (MCP) can be used as the detector for the total fluorescence yield (TFY) method by applying a sufficiently high negative bias to a grid in front of the MCP. However, this method often suffe...

متن کامل

A vacuum-compatible wet-specimen chamber for compact X-ray microscopy.

Soft X-ray microscopy is a powerful tool for investigations of, for example, polymers or soils in their natural liquid environment. This requires a wet-specimen chamber. Compact X-ray microscopy allows the horizontal mounting of such samples, thereby reducing the influence of gravitational forces. We have developed a wet-specimen chamber for such compact X-ray microscope. The chamber is vacuum ...

متن کامل

Ultra Soft X-ray Absorption Spectroscopy and Photoelectron Spectroscopy Studies on Related Materials and Cathodes of Lithium Ion batteries

For analysis of lithium ion batteries, the ultra soft X-ray absorption spectroscopy beamline BL-2 at SR center of Ritsumeikan University has been improving: adding the new grating (900 l/mm) to the monochromator for higher energy up to 1000eV, and constructing the XAFS-PES (photoelectron spectroscopy) chamber equipped with in-situ transfer vessel systems. To elucidate the performance of this be...