Incremental dynamic computed tomography: practical method of imaging the carotid bifurcation.
نویسندگان
چکیده
A simple, practical method of applying incremental dynamic computed tomography (CT) to the imaging of 20 carotid bifurcations is described. The results are compared with those obtained by conventional carotid angiography and intravenous digital subtraction angiography (DSA). Conventional angiography provided additional information about the carotid bifurcation in only one of 14 cases, while incremental dynamic CT provided information not available from intravenous DSA in two of eight cases. Conventional brain CT is being used increasingly in the workup of patients with transient ischemic symptoms, and dynamic CT scanning at 3-mm increments requires only an extra 5 min of scanner time. The addition of incremental dynamic CT through the carotid bifurcation to the conventional brain CT scan procedure may obviate other screening tests before more definitive angiographic procedures.
منابع مشابه
Examination of the Extracranial Carotid Bifurcation by Thin-Section Dynamic CT: Direct Visualization of Intimal Atheroma
Because carotid angiography has been shown to have limitations in the detection of intimal disease at the bifurcation, a new method of examination of the extracranial carotid artery has been developed using thin-section dynamic computed tomographic (CT) scanning. Carotid atheroma and thrombi can be imaged directly on these sections. The intimal lesions are uniformly hypodense with respect to th...
متن کاملExamination of the extracranial carotid bifurcation by thin-section dynamic CT: direct visualization of intimal atheroma in man (Part 1).
Because carotid angiography has been shown to have limitations in the detection of intimal disease at the bifurcation, a new method of examination of the extracranial carotid artery has been developed using thin-section dynamic computed tomographic (CT) scanning. Carotid atheroma and thrombi can be imaged directly on these sections. The intimal lesions are uniformly hypodense with respect to th...
متن کاملApproximate Incremental Dynamic Analysis Using Reduction of Ground Motion Records
Incremental dynamic analysis (IDA) requires the analysis of the non-linear response history of a structure for an ensemble of ground motions, each scaled to multiple levels of intensity and selected to cover the entire range of structural response. Recognizing that IDA of practical structures is computationally demanding, an approximate procedure based on the reduction of the number of ground m...
متن کاملAssessment of radiation-induced cancer risk to patients undergoing computed tomography angiography scans
Background: Computed tomography angiography (CTA) scan is a suitable imaging technique to evaluate the blood vessels. However, one major disadvantage is the potential risk of cancer related to ionizing radiation exposure during the procedures. The aim of this investigation was to estimate the risk of exposure induced cancer death (REID) values for some common computed tomography angiography (CT...
متن کاملDoes the principle of minimum work apply at the carotid bifurcation: a retrospective cohort study
BACKGROUND There is recent interest in the role of carotid bifurcation anatomy, geometry and hemodynamic factors in the pathogenesis of carotid artery atherosclerosis. Certain anatomical and geometric configurations at the carotid bifurcation have been linked to disturbed flow. It has been proposed that vascular dimensions are selected to minimize energy required to maintain blood flow, and tha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJR. American journal of roentgenology
دوره 146 3 شماره
صفحات -
تاریخ انتشار 1986