Comparison of an industry-derived LCx Chlamydia pneumoniae PCR research kit to in-house assays performed in five laboratories.
نویسندگان
چکیده
In a multicenter comparison of PCR assays utilizing 120 quantitated samples of 16 Chlamydia pneumoniae isolates, an LCx research-use-only (RUO) PCR developed by Abbott Laboratories demonstrated 100% sensitivity on 48 samples with >1 copy of DNA per microl of specimen. The sensitivities of five in-house PCR assays ranged from 54 to 94% for the same samples. All six assays showed decreased sensitivities as the DNA copy numbers of the samples decreased. Overall, sensitivities ranged from 68% for the LCx PCR assay to 29% for one of the in-house tests. The LCx RUO PCR and three of the five in-house PCR tests reported no false positives with the 24 negative samples. Increasing the number of replicates tested increased the sensitivities of all of the assays, including the LCx PCR. The LCx RUO assay showed high reproducibility for a single technologist and between technologists, with a kappa agreement of 0.77. The within-center agreements of the five in-house PCR tests varied from 0.19 to 0.74 on two challenges of 60 specimens 1 month apart. The LCx C. pneumoniae RUO PCR shows excellent potential for use in clinical studies, which could enable standardization of results in the field.
منابع مشابه
Reliability of nucleic acid amplification methods for detection of Chlamydia trachomatis in urine: results of the first international collaborative quality control study among 96 laboratories.
The first European Quality Control Concerted Action study was organized to assess the ability of laboratories to detect Chlamydia trachomatis in a panel of urine samples by nucleic acid amplification tests (NATs). The panel consisted of lyophilized urine samples, including three negative, two strongly positive, and five weakly positive samples. Ninety-six laboratories in 22 countries participat...
متن کاملEvaluation of amplicor chlamydia PCR and LCX chlamydia LCR to detect Chlamydia trachomatis in synovial fluid.
OBJECTIVES PCR has been successfully used in research for the detection of C. trachomatis DNA in synovial samples. However, each research laboratory has developed its own PCR, making inter-laboratory comparisons difficult. To allow for standardization we evaluated two commercially available amplification systems originally designed for the examination of urogenital samples (Roche Amplicor Chlam...
متن کاملEvaluation of five commercial real-time PCR assays for detection of Mycoplasma pneumoniae in respiratory tract specimens.
The performances of five commercial TaqMan real-time PCR assays for the detection of Mycoplasma pneumoniae in respiratory tract specimens were evaluated in comparison with an in-house real-time PCR. All kits allowed prompt and specific results, validated by the use of an internal control. The Nanogen kit showed the best clinical sensitivity.
متن کاملMinimal inhibitory effect of male urine on detection of Chlamydia trachomatis by Roche Amplicor PCR.
A total of 1120 specimens of fresh urine from male patients was tested for Chlamydia trachomatis with the Roche Amplicor PCR Kit and an in-house PCR assay. The in-house PCR had an internal control to monitor inhibitory effects of clinical specimens on the PCR assay. All urine samples were processed within 24-48 h of collection and DNA was extracted on the same day that the assays were performed...
متن کاملEvaluation of five real - time PCR assays for detection of Mycoplasma pneumoniae 7 8 Running title : Real - time PCR for detection of
25 Four commercial real-time PCR assays to detect M. pneumoniae were tested and the results 26 compared with an in-house approach. Despite differences of crossing threshold values up to 4, 27 assays were able to detect at least 20 cfu/5 μl (52 fg DNA/5 μl) of sample with best clinical 28 sensitivity of Diagenode kit. 29
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 40 7 شماره
صفحات -
تاریخ انتشار 2002