Prosthesis oversizing in balloon-expandable transcatheter aortic valve implantation is associated with contained rupture of the aortic root.

نویسندگان

  • Philipp Blanke
  • Jochen Reinöhl
  • Christian Schlensak
  • Matthias Siepe
  • Gregor Pache
  • Wulf Euringer
  • Annette Geibel-Zehender
  • Christopher Bode
  • Mathias Langer
  • Friedhelm Beyersdorf
  • Manfred Zehender
چکیده

BACKGROUND To retrospectively investigate the potential cause of contained rupture of the aortic root in balloon-expandable transcatheter aortic valve implantation (TAVI) by means of pre- and postinterventional multislice computed tomography. METHODS AND RESULTS Seventy-two patients (mean age 82±7 years, mean aortic valve area 0.69±0.19 cm(2)) underwent balloon-expandable TAVI using the EdwardsSAPIEN Transcatheter Heart Valve (23 mm, n=19; 26 mm, n=50; 29 mm, n=3). Aortic annulus dimensions were quantified by multislice computed tomography-based cross-sectional area assessment and average diameter calculation (CAAD) before and after TAVI. Post-TAVI multislice computed tomography data sets were available in 65 patients; contained aortic root rupture was diagnosed in 3 patients. Pre-TAVI CAAD was 23.1±1.8 mm; post-TAVI CAAD was 22.9±1.3 mm. Median relative change in CAAD pre- and post-TAVI was -0.5% (interquartile range, 3.6%). Relative increase of 5% to 10% was observed in 4 patients (1 with contained rupture), relative increase >10% in 2 patients, both with contained rupture. Mean relative oversizing, calculated as the relative difference in diameter between pre-TAVI CAAD and nominal diameter of the selected prosthesis, was 9.8%±7.8%. Relative oversizing was significantly higher in patients with contained rupture compared with patients without contained rupture (24.6%±5.4% versus 9.1%±6.6%; P<0.001). Relative oversizing ≥20% occurred in 6 patients (3 with contained rupture). CONCLUSIONS Contained rupture of the aortic root in balloon-expandable TAVI is associated with severe prosthesis oversizing. Multislice computed tomography-based assessment of aortic annulus dimension in conjunction with adapted sizing guidelines may reduce the incidence of severe oversizing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement.

BACKGROUND Aortic root rupture is a major concern with balloon-expandable transcatheter aortic valve replacement (TAVR). We sought to identify predictors of aortic root rupture during balloon-expandable TAVR by using multidetector computed tomography. METHODS AND RESULTS Thirty-one consecutive patients who experienced left ventricular outflow tract (LVOT)/annular/aortic contained/noncontained...

متن کامل

Predictors of Permanent Pacemaker Implantations and New-Onset Conduction Abnormalities With the SAPIEN 3 Balloon-Expandable Transcatheter Heart Valve.

OBJECTIVES This study investigates the influence of implantation depth and prosthesis oversizing on conduction abnormalities (CA) and permanent pacemaker implantation (PPI) after SAPIEN 3 (Edwards Lifesciences, Irvine, California) implantation. BACKGROUND CA and PPIs are frequent complications after transcatheter aortic valve replacement with a next-generation balloon-expandable transcatheter...

متن کامل

Increased Pacemaker Implantation Rate After New-Generation Balloon-Expandable SAPIEN 3 Valve: Who Was to Blame, the Valve or the Doctor?

SEE PAGE 805 T he occurrence of conduction disturbances and the need for permanent pacemaker implantation remain a significant issue associated with transcatheter aortic valve replacement (TAVR) (1). Indeed, the contiguity of the conduction system to the aortic annulus (landing zone of transcatheter valve prostheses) makes this procedure likely to develop this complication (2). To date, several...

متن کامل

Evaluation and management of paravalvular aortic regurgitation after transcatheter aortic valve replacement.

Paravalvular aortic regurgitation (PAR) negatively affects the prognosis after transcatheter aortic valve replacement (TAVR) with dramatically increased morbidity and mortality in patients with more than mild PAR. Because transcatheter heart valves are implanted in a sutureless fashion using oversizing to anchor the prosthesis stent frame at the level of the virtual aortic annulus, stent frame ...

متن کامل

Transcatheter aortic valve implantation with balloonexpandable valve: early experience from China

OBJECTIVE The aim of the current study was to evaluate the early experience of the application of transcatheter aortic valve implantation with the balloon-expandable system in China. The transcatheter aortic valve implantation technology has been widely used for patients with inoperable severe aortic stenosis in the developed world. The application of transcatheter aortic valve implantation is ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 5 4  شماره 

صفحات  -

تاریخ انتشار 2012