Evaluation of the MB/BacT system and comparison to the BACTEC 460 system and solid media for isolation of mycobacteria from clinical specimens.

نویسندگان

  • P Rohner
  • B Ninet
  • C Metral
  • S Emler
  • R Auckenthaler
چکیده

The MB/BacT automated system is designed for the isolation of mycobacteria from clinical specimens. It utilizes a colorimetric sensor and reflected light to continuously monitor the CO2 concentration in the culture medium. We compared its performance to that of the BACTEC 12B media for the radiometric BACTEC 460 instrument and that of solid culture media. Respiratory specimens and urine samples were decontaminated with 4% NaOH. The vials of the two instruments were inoculated with 500 microl of sample and two solid egg-based media at 200 microl each. All vials were incubated at 37 degrees C for 6 weeks. A total of 1,078 specimens (633 respiratory specimens, 78 cerebrospinal fluid specimens, 177 other body fluid specimens, 87 urine specimens, and 103 other types of specimens) were cultured in parallel. Mycobacteria could be identified from 73 (6.8%) specimens: 67 M. tuberculosis, 3 M. kansasii, 1 M. xenopi, 1 M. terrae, and 1 mixed M. avium with M. scrofulaceum. Of these, 63 (86.3%) specimens were positive with the MB/BacT system, 67 (91.8%) were positive with the BACTEC 460 instrument, and 58 (79.5%) were positive with the two egg-based media. MB/BacT cultures were positive on average after 17.5 (+/-6.4) days, BACTEC cultures with a growth index of >20 (mean, 200) were positive after 14.3 (+/-8.2) days, and egg-based media were positive after 24.2 (+/-7.5) days. Microorganisms other than mycobacteria contaminated 46 (4.3%) MB/BacT cultures and 31 (2.9%) BACTEC cultures, which had to be discarded. The MB/BacT system is a well-automated system for the detection of M. tuberculosis in clinical specimens without using radioactive reagents. Further trials are required to determine whether it is suitable for the culture of nontuberculous mycobacteria.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the MB/BacT and BACTEC 460 TB systems for recovery of mycobacteria from various clinical specimens.

A total of 1,830 specimens (75.7% respiratory and 24.3% nonrespiratory) were cultured in parallel with the MB/BacT and BACTEC 460 TB systems and on Lowenstein-Jensen (LJ) medium. Mycobacteria were identified from 173 (6.5%) specimens. The most common species recovered were Mycobacterium tuberculosis complex (65. 9%), Mycobacterium avium complex (22.5%), and Mycobacterium chelonae (9.2%). The re...

متن کامل

Comparison of the MB/BacT and BACTEC 460 TB systems.

We have read the recent report by Brunello et al. (1) about a comparative study between the MB/BacT and the BACTEC 460 TB systems for recovery of mycobacteria. We have carried out a similar study with 500 clinical specimens (89% respiratory and 24.3% nonrespiratory), and we would like to make some comments. First, like Brunello et al., we did not find any statistically significant differences b...

متن کامل

Comparison of MB/BacT and BACTEC 460 TB systems for recovery of mycobacteria in a routine diagnostic laboratory.

MB/BacT, BACTEC 460 TB, and Löwenstein-Jensen (LJ) medium were evaluated in parallel for recovery of mycobacteria from 3,700 continuous clinical specimens in a routine laboratory. Mycobacteria were identified from 123 (3.3%) specimens. The recovery rates for all mycobacteria by the different systems were 91.0, 73.0, and 53.6% for BACTEC 460 TB, MB/BacT, and LJ medium, respectively. The recovery...

متن کامل

Rapid detection of mycobacteria in clinical specimens by using the automated BACTEC 9000 MB system and comparison with radiometric and solid-culture systems.

Recovery rates of acid-fast bacilli (AFB) and the mean time to their detection from clinical specimens were determined by using the fluorescent BACTEC 9000 MB system. Data were compared to those assessed by the radiometric BACTEC 460 system and by cultivation on solid media. A total of 3,095 specimens were processed with N-acetyl-L-cysteine-NaOH by two laboratories. The contamination rates for ...

متن کامل

Two liquid medium systems, mycobacteria growth indicator tube and MB redox tube, for Mycobacterium tuberculosis isolation from sputum specimens.

Two manual liquid medium systems, the Mycobacteria Growth Indicator Tube (MGIT) and MB Redox tube systems, were evaluated in comparison to the radiometric BACTEC-460 semiautomated system for recovery of Mycobacterium tuberculosis from sputum specimens. The highest level of recovery, from a total of 77 culture-positive specimens, occurred with the BACTEC-460 system (92.2%), followed by the MB Re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 35 12  شماره 

صفحات  -

تاریخ انتشار 1997