Endovascular occlusion of aneurysms using a new bioactive coil: a matched pair analysis with bare platinum coils.
نویسندگان
چکیده
BACKGROUND AND PURPOSE To assess safety and efficacy data of a new bioactive coil (Cerecyte) which is loaded with polyglycolic acid on the inside of the coil. METHODS Fifty-four patients harboring 55 aneurysms were treated with Cerecyte coils. These aneurysms were matched in localization and size with aneurysms treated with bare platinum coils. RESULTS Periprocedural complications and handling did not differ between both groups. Initial aneurysm occlusion was comparable in both treatment groups. At 6 months angiographic follow-up, the aneurysms occluded with Cerecyte coils had a higher chance for complete occlusion (P=0.045) and tended to a lower retreatment rate (P=0.056). CONCLUSIONS Cerecyte coils are as safe as bare platinum coils in the endovascular occlusion of aneurysms. This matched pair analysis indicates a higher occlusion rate of aneurysms occluded with Cerecyte coils.
منابع مشابه
Matrix detachable coils for the endovascular treatment of intracranial aneurysms: analysis of early angiographic and clinical outcomes.
BACKGROUND AND PURPOSE Endovascular coil embolization has become an accepted alternative for the treatment of intracranial aneurysms. The purpose of this study was to evaluate the clinical safety and the angiographic stability of aneurysm occlusion with a new class of biologically active platinum coils after a 6-month period. METHODS Twenty-five patients with 25 intracranial aneurysms were tr...
متن کاملCerecyte coils in the treatment of intracranial aneurysms: a preliminary clinical study.
BACKGROUND AND PURPOSE Recanalization remains a major drawback in the endovascular treatment of intracranial aneurysms. Here, we report on our preliminary clinical experience with a new bioactive coil. PATIENTS AND METHODS In a prospective study, 25 aneurysms were treated in 24 patients. Endovascular occlusion of the aneurysm was performed by using a novel polyglycol acid-loaded coil (Cerecyt...
متن کاملShort-term outcome of intracranial aneurysms treated with polyglycolic acid/lactide copolymer-coated coils compared to historical controls treated with bare platinum coils: a single-center experience.
BACKGROUND AND PURPOSE Aneurysm recanalization is an innate problem in endovascular treatment of aneurysms with coils. A coated coil system, covered with a bioabsorbable polymeric material (polyglycolic acid/lactide copolymer, PGLA), was developed to accelerate intra-aneurysmal clot organization and fibrosis. The purpose of this study was to evaluate the efficacy and safety of the PGLA-coated c...
متن کاملEndovascular treatment with bare platinum coils for middle cerebral artery aneurysms.
Middle cerebral artery (MCA) aneurysms often have unfavorable anatomical characteristics preventing successful endovascular occlusion. We reviewed the outcomes of our series of endosaccular embolization of MCA aneurysms using bare platinum coils, angiographic images, and medical records. Immediate and follow-up angiographic results were categorized as complete occlusion, residual neck, and resi...
متن کاملSingle-center experience of cerecyte coils in the treatment of intracranial aneurysms: initial experience and early follow-up results.
BACKGROUND AND PURPOSE Endovascular treatment of intracranial aneurysms using platinum coils is effective, but uncommonly aneurysms recur. New-generation coils, such as Cerecyte, aim to address this problem. This study examines the safety and efficacy of these coils in the treatment of a cohort of ruptured and unruptured aneurysms MATERIALS AND METHODS Sixty-seven patients with 68 aneurysms w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stroke
دوره 38 10 شماره
صفحات -
تاریخ انتشار 2007