Physiological impact of patent foramen ovale on pulmonary gas exchange, ventilatory acclimatization, and thermoregulation.

نویسندگان

  • Andrew T Lovering
  • Jonathan E Elliott
  • James T Davis
چکیده

The foramen ovale, which is part of the normal fetal cardiopulmonary circulation, fails to close after birth in ∼35% of the population and represents a potential source of right-to-left shunt. Despite the prevalence of patent foramen ovale (PFO) in the general population, cardiopulmonary, exercise, thermoregulatory, and altitude physiologists may have underestimated the potential effect of this shunted blood flow on normal physiological processes in otherwise healthy humans. Because this shunted blood bypasses the respiratory system, it would not participate in either gas exchange or respiratory system cooling and may have impacts on other physiological processes that remain undetermined. The consequences of this shunted blood flow in PFO-positive (PFO+) subjects can potentially have a significant, and negative, impact on the alveolar-to-arterial oxygen difference (AaDO2), ventilatory acclimatization to high altitude and respiratory system cooling with PFO+ subjects having a wider AaDO2 at rest, during exercise after acclimatization, blunted ventilatory acclimatization, and a higher core body temperature (∼0.4(°)C) at rest and during exercise. There is also an association of PFO with high-altitude pulmonary edema and acute mountain sickness. These effects on physiological processes are likely dependent on both the presence and size of the PFO, with small PFOs not likely to have significant/measureable effects. The PFO can be an important determinant of normal physiological processes and should be considered a potential confounder to the interpretation of former and future data, particularly in small data sets where a significant number of PFO+ subjects could be present and significantly impact the measured outcomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

AltitudeOmics: impaired pulmonary gas exchange efficiency and blunted ventilatory acclimatization in humans with patent foramen ovale after 16 days at 5,260 m.

A patent foramen ovale (PFO), present in ∼40% of the general population, is a potential source of right-to-left shunt that can impair pulmonary gas exchange efficiency [i.e., increase the alveolar-to-arterial Po2 difference (A-aDO2)]. Prior studies investigating human acclimatization to high-altitude with A-aDO2 as a key parameter have not investigated differences between subjects with (PFO+) o...

متن کامل

Heart Carcinoid Disease with Patent Foramen Ovale Treated by Mini Sternotomy

This case report was an attempt to present the importance of diagnostic echocardiography and closure of a patent foramen ovale in carcinoid heart disease. Herein, we present a case of a 48-year-old woman with a carcinoid metastasis presenting with tricuspid regurgitation, pulmonic stenosis, patent foramen ovale, and borderline left ventricular ejection fraction on an echocardiogram. Surgical in...

متن کامل

Detection of Intracardiac and Intrapulmonary Shunts at Rest and During Exercise Using Saline Contrast Echocardiography

Ultrasound has become a valuable tool for making non-invasive physiological measurements that are clinically important, one of which is detection of anatomic shunts using saline contrast echocardiography. Right-to-left intrapulmonary and intracardiac shunts are clinically relevant for two reasons. First, they allow deoxygenated blood to mix with oxygenated blood, thereby reducing the overall ef...

متن کامل

Effect of a patent foramen ovale on pulmonary gas exchange efficiency at rest and during exercise.

The prevalence of a patent foramen ovale (PFO) is ~30%, and this source of right-to-left shunt could result in greater pulmonary gas exchange impairment at rest and during exercise. The aim of this work was to determine if individuals with an asymptomatic PFO (PFO+) have greater pulmonary gas exchange inefficiency at rest and during exercise than subjects without a PFO (PFO-). Separated by 1 h ...

متن کامل

Gas exchange detection of exercise-induced right-to-left shunt in patients with primary pulmonary hypertension.

BACKGROUND Because of high pulmonary vascular resistance in patients with primary pulmonary hypertension (PPH), right atrial pressure may exceed left atrial pressure during exercise, resulting in a right-to-left shunt via a patent foramen ovale (PFO). This shunting would disturb arterial PCO2 and H+ homeostasis if the pulmonary blood were not simultaneously hyperventilated to compensate for the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 121 2  شماره 

صفحات  -

تاریخ انتشار 2016