Visualization of epicardial cryoablation lesions using endogenous tissue fluorescence.

نویسندگان

  • Luther Swift
  • Daniel A B Gil
  • Rafael Jaimes
  • Matthew Kay
  • Marco Mercader
  • Narine Sarvazyan
چکیده

BACKGROUND Percutaneous cryoballoon ablation is a commonly used procedure to treat atrial fibrillation. One of the major limitations of the procedure is the inability to directly visualize tissue damage and functional gaps between the lesions. We seek to develop an approach that will enable real-time visualization of tissue necrosis during cryo- or radiofrequency ablation procedures. METHODS AND RESULTS Cryoablation of either blood-perfused or saline-perfused hearts was associated with a marked decrease in nicotinamide adenine dinucleotide (NADH) fluorescence, leading to a 60% to 70% loss of signal intensity at the lesion site. The total lesion area observed on the NADH channel exhibited a strong correlation with the area identified by triphenyl tetrazolium staining (r=0.89, P<0.001). At physiological temperatures, loss of NADH became visually apparent within 26±8 s after detachment of the cryoprobe from the epicardial surface and plateaued within minutes after which the boundaries of the lesions remained stable for several hours. The loss of electrical activity within the cryoablation site exhibited a close spatial correlation with the loss of NADH (r=0.84±0.06, P<0.001). Cryoablation led to a decrease in diffuse reflectance across the entire visible spectrum, which was in stark contrast to radiofrequency ablation that markedly increased the intensity of reflected light at the lesion sites. CONCLUSIONS We confirmed the feasibility of using endogenous NADH fluorescence for the real-time visualization of cryoablation lesions in blood-perfused cardiac muscle preparations and revealed similarities and differences between imaging cryo- and radiofrequency ablation lesions when using ultraviolet and visible light illumination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of endogenous NADH fluorescence for real-time in situ visualization of epicardial radiofrequency ablation lesions and gaps.

Radiofrequency ablation (RFA) aims to produce lesions that interrupt reentrant circuits or block the spread of electrical activation from sites of abnormal activity. Today, there are limited means for real-time visualization of cardiac muscle tissue injury during RFA procedures. We hypothesized that the fluorescence of endogenous NADH could be used as a marker of cardiac muscle injury during ep...

متن کامل

A randomized double-blind study of epicardial left atrial cryoablation for permanent atrial fibrillation in patients undergoing mitral valve surgery: the SWEDish Multicentre Atrial Fibrillation study (SWEDMAF).

AIMS The efficacy of epicardial left atrial (LA) cryoablation in eliminating atrial fibrillation (AF) in patients undergoing mitral valve surgery (MVS) is unknown. We hypothesized that MVS combined with LA cryoablation is superior to MVS alone. METHODS AND RESULTS Sixty-nine patients with permanent AF, included at four centres, underwent MVS with or without epicardial LA cryoablation. The pri...

متن کامل

Histological findings induced by different energy sources in experimental atrial ablation in sheep.

The aim of this study was a detailed comparative investigation of acute cardiac alterations induced by different energy sources and approaches in a sheep model. Experiments were performed on 39 sheep. Circular lesions were created endo- or epicardially in the left atrium and at the pulmonary veins using different energy sources: cryo, microwave, laser and unipolar or bipolar radiofrequency (RF)...

متن کامل

Echocardiographic Epicardial Adipose Tissue as a New Indicator of Cardiovascular Risk

Abstract Background and Purpose: Epicardial fat is the true visceral fat located around the heart, particularly around sub-epicardial coronary arteries that may locally interact and modulate the coronary arteries and myocardium through paracrine or vasocrine secretion of anti-inflammatory and proatherogenic cytokines. Most previous studies have used echocardiography and reported controversia...

متن کامل

Hybrid Epicardial and Endocardial Ablation of Atrial Fibrillation: Is Ablation on Two Sides of the Atrial Wall Better Than One?

Evolution of Surgical Ablation of Atrial Fibrillation T he success of catheter ablation of atrial fibrillation has continued to increase with the introduction of new technology, additional experience, and advances in our understanding of the targets of ablation. Nevertheless, patients with symptomatic drug refractory long-standing atrial fibrillation present a particular challenge for treatment...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 7 5  شماره 

صفحات  -

تاریخ انتشار 2014