Time-of-flight intracranial MR venography: evaluation of the sequential oblique section technique.

نویسندگان

  • J S Lewin
  • T J Masaryk
  • A S Smith
  • P M Ruggieri
  • J S Ross
چکیده

PURPOSE To implement a time-of-flight MR angiographic technique using the oblique acquisition of thin gradient-echo sections to evaluate the intracranial venous system, and to assess the feasibility of application of this technique in a routine clinical setting. METHODS The MR angiographic technique consisted of a two-dimensional gradient-echo technique with sequential overlapped sections obtained with an oblique orientation, angled from the sagittal toward the coronal plane. Parameters were evaluated during 41 measurements in 21 healthy volunteers with the section orientation varying from direct sagittal to direct coronal, followed by 64 examinations in 53 patients with an angle of obliquity of 15 degrees to 20 degrees from the sagittal toward the coronal plane. Confirmation of MR venographic findings was through correlation with clinical data and imaging studies. RESULTS The volunteer data demonstrated optimal visibility of the smaller midline structures with an angle of obliquity of 15 degrees or greater. Patient examinations with this angle demonstrated sinus obstruction or thrombosis (n = 11), sinus compression (n = 2), and apparent sinus stenosis (n = 1). CONCLUSIONS Oblique-acquisition time-of-flight MR venography seems to provide a rapid, robust technique for intracranial venous examination and can be applied as a useful adjunct to parenchymal MR in the evaluation of suspected venoocclusive disease. This oblique technique demonstrated improved vessel contrast over direct sagittal acquisition, required significantly fewer sections and thus a shorter acquisition time than direct coronal acquisition, and was applied without difficulty in the vast majority of patients in the clinical setting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of real-time three-dimensional gadolinium-enhanced elliptic centric-ordered MR venography and two-dimensional time-of-flight MR venography of the intracranial venous system.

BACKGROUND To compare 3-dimensional gadolinium-enhanced elliptic centric-ordered (3D GEC) magnetic resonance venography (MRV) with traditional 2-dimensional time-of-flight (2D TOF) MRV for imaging of the intracranial venous system. METHODS Fifty-three patients underwent 2D and 3D MRV, whereby venous structures were evaluated by 2 neuroradiologists. RESULTS Of the 53 patients, 10 were diagno...

متن کامل

3T high-spatial-resolution contrast-enhanced MR angiography of the intracranial venous system with parallel imaging.

The diagnostic image quality of contrast-enhanced (CE) 3D MR venography (MRV) was prospectively compared with that of 2D time-of-flight (TOF) MRV and contrast-enhanced 3D magnetization-prepared rapid acquisition of gradient echo (MPRAGE) sequences for the visualization of the intracranial venous system at 3T in 22 patients. CE MRV provides high-quality images and was shown to be superior to TOF...

متن کامل

Evaluation of the intracranial dural sinuses with a 3D contrast-enhanced MP-RAGE sequence: prospective comparison with 2D-TOF MR venography and digital subtraction angiography.

BACKGROUND AND PURPOSE The diagnosis of dural sinus thrombosis is often difficult because of its variable and nonspecific clinical presentation and the overlapping signal intensities of thrombosis and venous flow on conventional MR images and MR venograms. We compared 3D contrast-enhanced magnetization-prepared rapid gradient-echo (MP-RAGE) sequences with 2D time-of-flight (TOF) MR venography, ...

متن کامل

Evaluation of cerebral aneurysms with high-resolution MR angiography using a section-interpolation technique: correlation with digital subtraction angiography.

BACKGROUND AND PURPOSE The objective was to evaluate the results of high-resolution, fast-speed, section-interpolation MR angiography and digital subtraction angiography (DSA), thereby examining the potential use of a primary noninvasive screening test for intracranial aneurysms. METHODS The images were obtained in 39 cerebral aneurysmal lesions from 30 patients with a time-of-flight MR angio...

متن کامل

Imaging of cerebral venous thrombosis: current techniques, spectrum of findings, and diagnostic pitfalls.

Cerebral venous thrombosis is a relatively uncommon but serious neurologic disorder that is potentially reversible with prompt diagnosis and appropriate medical care. Because the possible causal factors and clinical manifestations of this disorder are many and varied, imaging plays a primary role in the diagnosis. Magnetic resonance (MR) imaging, un-enhanced computed tomography (CT), unenhanced...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 15 9  شماره 

صفحات  -