Galvanostatic Entrapment of Penicillinase into Polytyramine Films and its Utilization for the Potentiometric Determination of Penicillin
نویسندگان
چکیده
A sensitive and reliable potentiometric biosensor for determination of penicillin has been developed by exploiting the self-limiting growth of the non-conducting polymer, polytyramine. Optimum polytyramine-penicillinase (PTy-PNCnase) films for potentiometric detection of penicillin were accomplished with monomer solutions which contained 0.03 M tyramine, 37 U/mL penicillinase, 0.01 M KNO3, and 3 mM penicillin with an applied current density of 0.8 mA/cm2 and an electropolymerisation time of 40 seconds. The potentiometric biosensor gave a linear concentration range of 3-283 μM for penicillin and achieved a minimum detectable concentration of 0.3 μM. The biosensor was successfully utilized for the detection of Amoxycillin and gave an average percentage recovery of 102±6%. Satisfactory recoveries of penicillin G were also achieved in milk samples with the potentiometric biosensor when concentrations are ≥20 ppm.
منابع مشابه
Isolation of a Penicillin Acylase Producing E.coli and Kinetic Characterization of the Whole Cell Enzyme Activity
Penicillin acylase (EC 3.5.1.11) has been a target of study for a long time because of its pivotal role in the deacylation of the penicillin into the 6- aminopenicillanic acid (6-APA) and the side-chain organic acids. This property of penicillin acylase has been exploited commercially for large scale production of 6-APA, which is the key intermediate in the manufacture of semi-synthetic penicil...
متن کاملNew Coated Graphite Potentiometric Sensor for Selective Determination of Copper (II) Ions
A highly selective copper (II) coated graphite sensor was prepared by 1,13-bis(8-quinolyl)- 1,4,7,10,13-pentaoxatridecane (kryptofix 5) as a supramolecule ionophore into plasticized polyvinyl chloride (PVC) membrane. The best response characteristic was observed using the membrane composition of PVC = 30.0 mg, dioctyl sebacate (DOS) = 63.5 mg, palmitic acid (PA) = 3.0 mg and kryptofix 5 = 3.5 m...
متن کاملResistance to penicillin and identification of penicillinase-producing Neisseria gonorrhoeae among clinical isolates in Thailand.
Penicillin-resistant Neisseria gonorrhoeae from 405 patients were studied by determination of penicillin minimal inhibitory concentrations an penicillinase production. Eighteen percent were identified as penicillin-producing N. gonorrhoeae and the mean minimal inhibitory concentration, for all except penicillin-producing strains, was 0.805 micrograms/ml.
متن کاملZnO Nanorods Based Enzymatic Biosensor for Selective Determination of Penicillin
In this study, we have successfully demonstrated the fabrication of a biosensor based on well aligned single-crystal zinc oxide (ZnO) nanorods which were grown on gold coated glass substrate using a low temperature aqueous chemical growth (ACG) method. The ZnO nanorods were immobilized with penicillinase enzyme using the physical adsorption approach in combination with N-5-azido-2-nitrobenzoylo...
متن کاملPenicillin biosensor based on a capacitive field-effect structure functionalized with a dendrimer/carbon nanotube multilayer.
Silicon-based sensors incorporating biomolecules are advantageous for processing and possible biological recognition in a small, reliable and rugged manufactured device. In this study, we report on the functionalization of field-effect (bio-)chemical sensors with layer-by-layer (LbL) films containing single-walled carbon nanotubes (SWNTs) and polyamidoamine (PAMAM) dendrimers. A capacitive elec...
متن کامل