Coronary Artery Revascularization Evaluation—A Multicenter Registry With Seven Years of Follow‐Up
نویسندگان
چکیده
BACKGROUND Data from randomized clinical trials comparing coronary artery bypass grafting (CABG) and percutaneous coronary intervention (PCI) may not accurately reflect current clinical practice, in which there is off-label usage of drug-eluting stents (DES). We undertook a prospective registry of coronary revascularization by CABG on- and off-pump and PCI with bare-metal stents (BMSs), DESs, or percutaneous transluminal coronary angioplasty (PTCA) to determine clinical outcomes. METHODS AND RESULTS All patients undergoing isolated coronary revascularization in 8 community-based hospitals were enrolled. Final follow-up was obtained after 5 years by patient and/or physician contact and the Social Security Death Index. ST-elevation myocardial infarction and salvage patients were excluded. Five or more years of follow-up was obtained on 81.5% (3156) of the eligible patients-968 CABG patients (82.0%) and 2188 PCI patients (81.3%). Overall follow-up was 63.5±27.9 months (median, 79.7 months). The incidence of initial major adverse cardiac events (MACEs) at follow-up for CABG versus PCI was 29.2% versus 41.8% (P<0.001). Analysis of stent subgroups showed more events with BMSs (equivalent to PTCA alone) compared with DESs. All stents had more events than on- or off-pump CABG groups. Using propensity score-matched groups, the odds ratio for CABG to PCI was 0.69 (95% confidence interval [CI], 0.56 to 0.85; P<0.001) for mortality and 0.58 (95% CI, 0.45 to 0.75; P<0.001) for any MACE. CONCLUSIONS In the current era of DES and off-pump surgery, in a community hospital setting, comparable patients undergoing coronary revascularization appear to benefit from improved long-term survival and reduced MACE with CABG versus PCI.
منابع مشابه
A case of multiple coronary artery aneurysms: Successful revascularization
Introduction: Multiple coronary artery aneurysm is a rare anomaly which could be congenital or acquired. Its complications including sudden cardiac death, clot and distal emboli, rupture and bleeding or fistula. Decision about its management depends on aneurysm conditions and the Patient's clinical situation Case Report: A 55 years old patient with unstable angina and multiple coronary ar...
متن کاملDoes Use of Bilateral Internal Mammary Artery Grafting Reduce Long-Term Risk of Repeat Coronary Revascularization? A Multicenter Analysis.
BACKGROUND Although previous studies have demonstrated that patients receiving bilateral internal mammary artery (BIMA) conduits during coronary artery bypass grafting have better long-term survival than those receiving a single internal mammary artery (SIMA), data on risk of repeat revascularization are more limited. In this analysis, we compare the timing, frequency, and type of repeat corona...
متن کاملInfluence of Sex on Long-Term Outcomes After Implantation of Bare-Metal Stent: A Multicenter Report From the Coronary Revascularization Demonstrating Outcome Study-Kyoto (CREDO-Kyoto) Registry Cohort-1.
BACKGROUND Female sex was reported to be associated with lower risk for midterm restenosis and repeat revascularization after bare-metal stent implantation. However, the influence of sex on very long-term outcomes after bare-metal stent implantation has not been yet reported. METHODS AND RESULTS Among the 9877 patients in the multicenter Coronary Revascularization Demonstrating Outcome study ...
متن کاملIncremental prognostic value of cardiac computed tomography in coronary artery disease using CONFIRM: COroNary computed tomography angiography evaluation for clinical outcomes: an InteRnational Multicenter registry.
BACKGROUND Large multicenter studies validating the prognostic value of coronary computed tomographic angiography (CCTA) and left ventricular ejection fraction (LVEF) are lacking. We sought to confirm the independent and incremental prognostic value of coronary artery disease (CAD) severity measured using 64-slice CCTA over LVEF and clinical variables. METHODS AND RESULTS A large internationa...
متن کاملSafety and effectiveness of the Endeavor zotarolimus-eluting stent in real-world clinical practice: 12-month data from the E-Five registry.
OBJECTIVES The E-Five registry was designed to evaluate the safety and effectiveness of the Endeavor zotarolimus-eluting stent (ZES) (Medtronic CardioVascular, Santa Rosa, California) for the treatment of coronary artery stenosis across a wide range of patients treated in real-world clinical practice settings. BACKGROUND Early clinical trials with the Endeavor ZES have demonstrated low rates ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2 شماره
صفحات -