Evaluation of radiation dose during pacemaker implantations.

نویسندگان

  • V Tsapaki
  • A Christou
  • S Spanodimos
  • N Nikolaou
  • A Poulianitou
  • Ch Triantopoulou
  • S Patsilinakos
چکیده

The purpose was to evaluate patient radiation doses and compare with other interventional procedures. One hundred and twenty-eight procedures were carried out with a recently installed mobile undercouch C-arm machine with a 23-cm diameter image intensifier. The radiation dose is provided by the X-ray machine, in terms of cumulative dose (CD). Kerma-Area product (KAP) was then estimated from CD and the X-ray field size. Other patient parameters recorded were patient weight, age, kilovolt, milliampere and fluoroscopy time (T). Median (range) CD, KAP and T were 15.2 mGy (3.2-110 mGy), 6.3 Gy cm(2) (1.3-45.7 Gy cm(2)) and 5.2 (1.5-27.4 min) min, respectively. Median E was 1.1 mSv (conversion factor: 0.18 mSv per Gy cm(2)), which corresponds to approximately one lumbar spine X-ray radiography. The effective dose is much lower than a coronary angiography (8 mSv) or an electrophysiology study (6 mSv). Radiation dose is low compared with other interventional cardiology procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The influence of neutron contamination on pacemaker in photon beam radiotherapy by LINAC using the Monte Carlo method

  In radiation therapy with high-energy photon beams (E > 10 MV) neutrons are generated mainly in LINACs head thorough (γ,n) interactions. These neutrons affect the shielding requirements in radiation therapy rooms. According to the AAPMTG-34 report, photon absorbed dose of 10Gy can cause permanent damage to the pacemaker and the dose of 2Gy can make minor changes in the functioning of the pac...

متن کامل

Siemens angiography and MediGuideTM Technology facilitate significant dose reduction during Cardiac Resynchronization Therapy (CRT)

The study showed reductions fluoroscopy time and radiation exposure of up to 90% when compared to conventional (exclusively fluoroscopy-guided) CRT implantations. There were no negative consequences on procedural efficacy and no complications. Background CRT and MediGuideTM Technology CRT is a well established therapy for patients with advanced Heart Failure (HF). The number of implantations is...

متن کامل

The influence of neutron contamination on pacemaker in photon beam radiotherapy by LINAC using the Monte Carlo method

Introduction: In radiation therapy with high-energy photon beams (E > 7 MeV) neutrons are generated mainly in LINACs head thorough (γ, n) interactions. These neutrons affect the shielding requirements in radiation therapy rooms. According to the protocol TG-34, photon absorbed dose of 10Gy can cause permanent damage to the pacemaker and the dose of 2Gy can make minor changes in...

متن کامل

Implantation of a dual-chamber permanent pacemaker in a pregnant patient guided by intracardiac echocardiography and electroanatomic mapping

Introduction Fluoroscopy has traditionally been the primary cardiac imaging modality to guide transvenous permanent pacemaker (PPM) implantations. This entails radiation exposure, which is often at a modest dose for individual patients but can be potentially hazardous to operators after cumulative doses. In patients who are pregnant, fluoroscopy is considered contraindicated. Many authors have ...

متن کامل

Designing a shield to reduce radiation dose during mammography: Dosimetric evaluation

Background: This paper presents a method to reduce radiation exposure during mammography by analysing the doses to ipsilateral and contralateral breasts and to adjacent organs by evaluating material-dependent shielding performance.  Materials and Methods: Six target-filter combinations (Mo-Mo, Mo-Rh, Rh-Rh, Rh-Mo, W-Mo, W-Rh) were tested by measuring the doses delivered to the breasts and adjac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 147 1-2  شماره 

صفحات  -

تاریخ انتشار 2011