An Optical Method for Determination of Weight Distribution in the Foot
نویسندگان
چکیده
The major technical challenge is to design the individual weight measuring point without using load cell or pressure sensor, since it will increase cost of the equipment. So our system incorporates low cost optical based weight measurement. In addition to this, we measure the severity of loss of sensation in the foot by introducing Vibro-tactile threshold sensation technique. By using this technique, the degree of loss of sensation can be determined for a diabetes patient. Our project has two foot plates in which one is designed with eight LED – LDR set up (sensor unit) and the other a dummy. Depending on the weight of the person, the intensity of light falling on the LDR from the LED varies. The detected signal is given to the ADC. The digital signal is processed by a microcontroller and the output
منابع مشابه
Comparison of plantar pressure distribution between the right and left foot and their correlation with height and weight at wrestlers
Since, sports activities are likely to be changes in various parameters of plantar pressure distribution during walking to create, This study compared patterns of plantar pressure distribution between right and left feet and their relationship with anthropometric parameters. 10 elite wrestler with the average and standard deviation of age: 23.6±3.33 yrs, height: 173.5±7.67 cm and mass: 83.3±21....
متن کاملAn Optical Method for Determination of Weight Distribution in the Foot
The major technical challenge is to design the individual weight measuring point without using load cell or pressure sensor, since it will increase cost of the equipment. So our system incorporates low cost optical based weight measurement. In addition to this, we measure the severity of loss of sensation in the foot by introducing Vibro-tactile threshold sensation technique. By using this tech...
متن کاملDetermination of 137Ba Isotope Abundances in Water Samples by Inductively Coupled Plasma-optical Emission Spectrometry Combined with Least-squares Support Vector Machine Regression
A simple and rapid method for the determination of 137Ba isotope abundances in water samples by inductively coupled plasma-optical emission spectrometry (ICP-OES) coupled with least-squares support vector machine regression (LS-SVM) is reported. By evaluation of emission lines of barium, it was found that the emission line at 493.408 nm provides the best results for the determination...
متن کاملMicrowave assisted digestion coupled with inductively coupled plasma optical emission spectrometry for determining element concentrations in halophytes
Introduction: This study was carried out to determine elements (Li, Na, K, Mg, Ca, Ba, B, Al, Si, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Ag and P) in the Suaeda vermiculata (S. vermiculata) and Suaeda aegyptiaca (S. aegyptiaca) in three different regions of Southern Iran using inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave-assisted acid digestion. Materials and ...
متن کاملDetermination of corrosion and sedimentation potential in drinking water distribution system of khorramabad city by corrosion indices and weight loss method
Pirialam R1, Shams khorramabadi Gh2, Shahmansouri MR3, Farzadkiya M4 1. MSc in Environmental Health, Lorestan University of Medical Sciences, Khorramabad, Iran 2. Assistant Professor, Department of Environmental Health, Faculty of Health, Lorestan University of Medical Sciences, Khorramabad, Iran 3. Associate Professor, Department of Environmental Health, Faculty of Health, Isfahan University o...
متن کامل