Validation of a protocol to evaluate maximal expiratory pressure using a pressure transducer and a signal conditioner.
نویسندگان
چکیده
The respiratory muscles can present fatigue and even chronic inability to generate force. So, reliable devices are necessary to their evaluation. The aim of this study is to evaluate the MEP (Maximal Expiratory Pressure) values of individuals between 20 and 25 years old and to validate a protocol using a pressure transducer and a signal conditioner comparing it with the digital manometer. We evaluated the MEP of 10 participants. They remained seated and made six respiratory maneuvers from Total Lung Capacity (TLC) to Residual Volume (RV). The results in the study showed no statistically significant differences when compared to values reported in the literature, and that the pressure transducer provides reliable values for MEP.
منابع مشابه
Response of Maximum Inspiratory Pressure and Functional Capacity to Positive End-Expiratory Pressure Device after Valvular Heart Surgery
Background: Pulmonary complications following valvular heart surgery are common and contribute to increased duration of hospital stay, rate of morbidity, and mortality. The purpose of the present study was to investigate the response of maximum inspiratory pressure and functional capacity to Positive End-Expiratory Pressure device in patients who underwent valvular hea...
متن کاملتخمین فشار متوسط شریانی توسط پایش تهاجمی فشار شریانی با مانومتر
Background: Direct monitoring of arterial pressure using a transducer system is not affordable in most operating rooms and ICU wards in Iran. It is, however, possible to use an aneroid manometer instead, but it is not standardized yet, nor studied enough and its measurements may not be interpretable. Methods: To study the correlation of the arterial pressure readings between a manometer and a ...
متن کاملPortable measurement of maximum mouth pressures.
We have compared a small portable mouth pressure meter (MPM) to our laboratory standard (LS) pressure recording equipment in order to evaluate this new device. The mouth pressure meter measures and displays as a digital read-out peak pressure for inspiratory and expiratory efforts. It samples the signal at 16 Hz, and an integral microprocessor is programmed to determine and display the maximum ...
متن کاملPositive Expiratory Pressure (PEP) versus Conventional Chest Physiotherapy in Pediatric Patients with Acute Exacerbation of Cystic Fibrosis
Background Pulmonary involvement is the main cause of mortality in cystic fibrosis (CF). Airway clearance techniques are non-pharmacological complement options for CF patients. The aim of this study was to evaluate the short-term outcome of airway cleaning treatment in patients with cystic fibrosis in a children's hospital. Materials and Methods This clinical trial study conducted on 40 CF pati...
متن کاملComparison of two methods of measurement of maximal respiratory pressures in health and cystic fibrosis
Introduction: Respiratory muscle strength can be assessed by static mouth measurements of maximal inspiratory pressure (Pimax) and maximal expiratory pressure (Pemax). Impaired respiratory muscle strength is common in neuromuscular and obstructive pulmonary disease such as Cystic Fibrosis (CF). Maximal respiratory pressures can easily be measured with a portable manometer on the bedside and in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anais da Academia Brasileira de Ciencias
دوره 83 3 شماره
صفحات -
تاریخ انتشار 2011