Title of Document : THIN - FILAMENT PYROMETRY WITH A DIGITAL STILL CAMERA
نویسندگان
چکیده
Title of Document: THIN-FILAMENT PYROMETRY WITH A DIGITAL STILL CAMERA Jignesh D. Maun, Master of Science, 2006 Directed By: Peter B. Sunderland, Assistant Professor, Department of Fire Protection Engineering A novel thin-filament pyrometer is presented here. It involves a consumer-grade color digital still camera with a charged-couple device sensor with 3008 × 2000 pixels and 12 bits per color plane. A blue Schott filter and custom white balance were used to yield similar red, green and blue intensities along the fibers. SiCO fibers with diameters of 13.9 μm were used and scanning-electron microscopy revealed the fibers to be uniform. Measurements were performed in a methane/air coflowing laminar jet diffusion flame with a luminosity length of 72 mm. Calibration of the pyrometer was accomplished with B-type thermocouple measurements. The camera was found to be well suited to thin-filament pyrometry. The pyrometry measurements yielded gas temperatures in the range of 1350 – 2200 K with an estimated uncertainty of ± 60 K, a relative temperature resolution of ± 0.215 K, a spatial resolution of 42 μm and a temporal resolution of 0.66 ms. Fiber aging had no effect on the results. Soot deposition was less problematic for the pyrometer than for the thermocouple. THIN-FILAMENT PYROMETRY WITH A DIGITAL STILL CAMERA
منابع مشابه
Thin-filament pyrometry with a digital still camera.
A novel thin-filament pyrometer is presented. It involves a consumer-grade color digital still camera with 6 megapixels and 12 bits per color plane. SiC fibers were used and scanning-electron microscopy found them to be uniform with diameters of 13.9 micro m. Measurements were performed in a methane-air coflowing laminar jet diffusion flame with a luminosity length of 72 mm. Calibration of the ...
متن کاملMeasurements of Soot Temperature in a Diffusion Flame Using a Digital Camera
Title of Document: Measurements of Soot Temperature in a Diffusion Flame Using a Digital Camera Jose Castillo Moreno, Master of Science, 2012 Directed by: Peter B. Sunderland, Associate Professor, Department of Fire Protection Engineering Temperatures were measured in a laminar axisymmetric diffusion flame with a digital camera. The camera was a Nikon D700, modified to remove the Infra-Red (IR)...
متن کاملDocument Image Dewarping Based on Text Line Detection and Surface Modeling (RESEARCH NOTE)
Document images produced by scanner or digital camera, usually suffer from geometric and photometric distortions. Both of them deteriorate the performance of OCR systems. In this paper, we present a novel method to compensate for undesirable geometric distortions aiming to improve OCR results. Our methodology is based on finding text lines by dynamic local connectivity map and then applying a l...
متن کاملStudy on Wicking Measurement in Thin Layer Textiles by Processing Digital Images
The purpose of this work is to assess and develop experimental techniques that allowwicking measurement over a wide range of textiles. Various kinds of fabrics, nonwoven layers and anelectro spinning nylon layer were used as the test materials. A syringe is used to drop a 0.02 g spot ofdistilled water on the sample and a digital camera to take pictures simultaneously. When the wickingprocess st...
متن کاملComparing The Power of the Intraoral Camera to the Digital Extraoral Camera in Diagnosis of Non metric Dental Morphologic Traits
Abstract Background and Aims :One of the method for studying nonmetric traits is intraoral photography pictures .The aim of this research is , Comparison of the power of the intraoral camera to a Extraoral camera to diagnose of morphologic non metric traits. Materials and Methods:In this diagnostic research we selected eligible samples ,among them at least 40 were without traits and 40 had ...
متن کامل