Effects of positive end-expiratory pressure on oscillated flow rate during high-frequency chest compression.

نویسندگان

  • R J Perry
  • G C Man
  • R L Jones
چکیده

OBJECTIVE To investigate the effects of positive end-expiratory pressure (PEEP) on end-expiratory lung volume (EELV) and mean oscillated flow rate (VOSC) during high-frequency chest compression (HFCC) in normal subjects and patients with severe COPD. DESIGN Comparative study. SETTING Pulmonary function and lung mechanics laboratory, University of Alberta Hospitals. PARTICIPANTS Six normal subjects (five male; one female) and six patients with clinically stable COPD (five male; one female) with hypercapnia. INTERVENTIONS A pneumatic vest system was operated at 10 Hz with a mean chest wall pressure of 16 cm H2O to provide the HFCC. A closed-circuit spirometer system permitted measurement of HFCC- and PEEP-induced changes in EELV that were expressed as per cent baseline functional residual capacity (FRC). An isothermic chamber connected near the mouthpiece permitted measurement of VOSC. RESULTS For the normal subjects, HFCC caused a significant decrease in EELV to 82.0% of FRC (p < or = 0.01) and the addition of 4.8+/-0.5 cm H2O of PEEP during HFCC increased EELV to 97.5% FRC. In the COPD patients, HFCC decreased EELV to 92.3% of FRC (p < or = 0.01), and the addition of 3.7+/-1.0 cm H2O of PEEP increased EELV to 98.4% FRC. For the normal subjects, increasing EELV to near FRC caused VOSC during expiration to increase 14.6% (p < or = 0.01), but there was no significant effect on VOSC during inspiration (5.1% increase). In the COPD patients, PEEP increased VOSC during both inspiration (30.5%) and expiration (57.0%) (both, p < or = 0.01). CONCLUSIONS Addition of a modest amount of PEEP during HFCC prevents the decrease in EELV and increases VOSC during both phases of spontaneous breathing in COPD patients. This higher VOSC during HFCC+PEEP may improve the effectiveness of HFCC in clearing mucus from the lungs of patients with airway disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Short-Term Effects of High-Frequency Chest Compression and Positive Expiratory Pressure in Patients With Cystic Fibrosis

BACKGROUND Cystic fibrosis patients require daily airway clearance therapies. The primary objective of this study was to compare the short-term efficacy of high-frequency chest compression and positive expiratory pressure mask on expectorated sputum, pulmonary function, and oxygen saturation in patients with CF hospitalized for an acute pulmonary exacerbation. METHODS A controlled randomized ...

متن کامل

Manual vibration increases expiratory flow rate via increased intrapleural pressure in healthy adults: an experimental study.

QUESTION What is the relationship between vibration of the chest wall and the resulting chest wall force, chest wall circumference,intrapleural pressure, and expiratory flow rate? Is the change in intrapleural pressure during vibration the sum of the intrapleural pressure due to recoil of the lung, chest wall compression, and chest wall oscillation? DESIGN Randomised, within-subject,experimen...

متن کامل

Response of Maximum Inspiratory Pressure and Functional Capacity to Positive End-Expiratory Pressure Device after Valvular Heart Surgery

Background: Pulmonary complications following valvular heart surgery are common and contribute to increased duration of hospital stay, rate of morbidity, and mortality. The purpose of the present study was to investigate the response of maximum inspiratory pressure and functional capacity to Positive End-Expiratory Pressure device in patients who underwent valvular hea...

متن کامل

Maximal expiratory flows generated by rapid chest compression following end-inspiratory occlusion or expiratory clamping in young children.

Partial forced expiratory flow-volume curves obtained by the rapid chest compression technique are being widely used to assess pulmonary function in infants and young children. The aim of this study is to assess whether in this age group flow limitation is achieved with the partial forced expiratory flow-volume curve with rapid chest compression. In eight infants and young children sedated with...

متن کامل

High-frequency assisted airway clearance.

High-frequency airway clearance assist devices generate either positive or negative transrespiratory pressure excursions to produce high-frequency, small-volume oscillations in the airways. Intrapulmonary percussive ventilation creates a positive transrespiratory pressure by injecting short, rapid inspiratory flow pulses into the airway opening and relies on chest wall elastic recoil for passiv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 113 4  شماره 

صفحات  -

تاریخ انتشار 1998