Modelling Temperature-induced Spectral Variations in Chemical Process Monitoring
نویسندگان
چکیده
With a view to ensuring the validity of multivariate calibration models in the presence of temperature variations, a new methodology, individual contribution standardization (ICS), is proposed to correct for temperature-induced spectral variations. The methodology was applied to shortwave NIR spectral data sets recorded at different temperatures. The results showed that ICS can almost eliminate temperature effects resulting in calibration models that exhibit good predictive performance. Compared with other methods, such as continuous piecewise direct standardization, ICS has the advantages of easy implementation, simple selection of the calibration model and less restrictions on the training samples. Copyright 2004 IFAC
منابع مشابه
Variations of water quality in the monitoring network of a tropical river
Rapid development and population growth have resulted in an ever-increasing level of water pollution in Malaysia. Therefore, this study was conducted to assess water quality of Selangor River in Malaysia. The data collected under the river water quality monitoring program by the Department of environment from 2005 to 2015 were used for statistical analyses. The local water quality indices were ...
متن کاملAn Investigation of Brightness Changes in Ultrasound Images due to Temperature Variations in Liver Tissue during Radiofrequency Ablation
Introduction: one of the minimally invasive methods of treatmenting liver malignancies is Radiofrequency Ablation (RFA) which can be applied to primary or secondary tumors. Nevertheless, the disease recurrence is probable after RFA application partially due to the inadequate capability of temperature monitoring of the target tissue and visualizing the thermal damage. The goal of this work was t...
متن کاملModelling of Mean Drop Size in a Extraction Spray Column and Developing a New Model
In the present investigation the biosorption potential of rosa gruss an teplitz (Red Rose) Waste Biomass (RRWB) for the removal of Pb(II) and Co(II) from aqueous solutions was studied. The effect of different process parameters such as pH, biosorbent dose, biosorbent size, temperature, contact time, initial metal concentration and pretreatments on the biosorption capacity of this waste biom...
متن کاملThermo-Electro Mechanical Impedance based Structural Health Monitoring: Euler- Bernoulli Beam Modeling
In recent years, impedance measurement method by piezoelectric (PZT) wafer activesensor (PWAS) has been widely adopted for non-destructive evaluation (NDE). In this method, theelectrical impedance of a bonded PWAS is used to detect a structural defect. The electro-mechanicalcoupling of PZT materials constructs the original principle of this method. Accordingly, the electricalimpedance of PWAS c...
متن کاملTwo-dimensional correlation analysis of visible/near-infrared spectral intensity variations of chicken breasts with various chilled and frozen storages.
Generalized two-dimensional (2D) correlation analysis of visible/near-infrared (NIR) spectra was performed to characterize the spectral intensity variations of chicken muscles induced by either storage time/temperature regime or shear force values. The results showed that intensities of two visible bands at 445 and 560 nm increase with the storage temperature under identical treatment, possibly...
متن کامل