Changes in the light intensity of the fiberoptic laryngoscope blade by steam sterilization.

نویسنده

  • Tomoki Nishiyama
چکیده

BACKGROUND I investigated the effects of steam sterilization on light intensity of reusable fiberoptic laryngoscope blades. METHODS Six new reusable fiberoptic Macintosh laryngoscope blades were steam sterilized. The light intensity was measured, the tip of the blades was photographed, and the light intensity of six new plastic disposable Macintosh laryngoscope blades was also measured. RESULTS The light intensity of reusable blades exceeded that of the disposable blades after 20 sterilizations, but was significantly lower after 80 sterilizations. The photographs showed irregular lighting of the blades, which increased with repeated sterilization. CONCLUSIONS Disposable plastic blades provide more illumination than reusable fiberoptic blades subjected to repeated sterilization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی شیوع آسیب به دندانها حین لوله‌گذاری تراشه بوسیله لارینگوسکوپ مکینتاش استاندارد در مقایسه با لارینگوسکوپ مکینتاش تغییریافته

ABSTRACT The Macintosh Laryngoscope has proved itself over half a century and is still one of the most popular laryngoscopes. Even in experienced hands, however, complications can occur notably damage to the maxillary incisors. Damage to teeth is reported to be the most common single reason for complaints against anesthesiologists. Dental injuries could be caused by friction or by contac...

متن کامل

Management of the Difficult Paediatric Airway with a Simple Fiberoptic-Assisted Laryngoscope: A Report of Two Cases with Pierre Robin and Patau's (Trisomy 13) Syndrome.

Airway management of children with congenital craniofacial anomalies is a challenge for paediatric anaesthesiologists. We do not have any video-assisted airway device in our department for difficult paediatric intubations. We decided to attach a regular fiberoptic (outer diameter; 3.7 mm, Karl Storz, Germany) scope to a conventional Macintosh Laryngoscope (size 1). We describe two cases of Pier...

متن کامل

WuScope Improves View in C-Spine Immobilized Intubations

Intubation during c-spine immobilization is inherently more difficult because of decreased glottic visualization. The WuScope is a rigid, fiberoptic laryngoscope designed to facilitate visualization and tracheal intubation without neck extension. In a randomized study, these authors compared the WuScope and conventional laryngoscopy with a Macintosh blade in 87 c-spine immobilized patients unde...

متن کامل

Metallurgical fatigue failure analysis of the brazed steam turbine blade

In this paper, failure mechanism of a 17th stage blade of an 82.5 MW steam turbine that caused damage to the internal turbine compartment and the adjacent blade equipment has been studied. In order to determine the cause of failure and prevent similar events, various metallurgical and mechanical investigations including chemical composition analysis, metallography and microstructural analysis, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 104 4  شماره 

صفحات  -

تاریخ انتشار 2007