Non-linear regularized phase retrieval for unidirectional X-ray differential phase contrast radiography.
نویسندگان
چکیده
Phase retrieval from unidirectional radiographic differential phase contrast images requires integration of noisy data. A method is presented, which aims to suppress stripe artifacts arising from direct image integration. It is purely algorithmic and therefore, compared to alternative approaches, neither additional alignment nor an increased scan time is required. We report on the theory of this method and present results using numerical as well as experimental data. The method shows significant improvements on the phase retrieval accuracy and enhances contrast in the phase image. Due to its general applicability, the proposed method provides a valuable tool for various 2D imaging applications using differential data.
منابع مشابه
Spline based iterative phase retrieval algorithm for X-ray differential phase contrast radiography.
Differential phase contrast imaging using grating interferometer is a promising alternative to conventional X-ray radiographic methods. It provides the absorption, differential phase and scattering information of the underlying sample simultaneously. Phase retrieval from the differential phase signal is an essential problem for quantitative analysis in medical imaging. In this paper, we formali...
متن کاملPhase retrieval in in-line x-ray phase contrast imaging based on total variation minimization.
State-of-the-art techniques for phase retrieval in propagation based X-ray phase-contrast imaging are aiming to solve an underdetermined linear system of equations. They commonly employ Tikhonov regularization - an L2-norm regularized deconvolution scheme - despite some of its limitations. We present a novel approach to phase retrieval based on Total Variation (TV) minimization. We incorporated...
متن کاملIn-line Phase-sensitive X-ray Imaging
10.2 Physics Principles of In-line X-ray Phase-contrast Imaging......................................145 10.2.1 Attenuation, Phase Shift, and Optical Transmission ...................................145 10.2.2 System Configuration of In-line Phase-contrast Imaging............................145 10.2.3 Theoretical Framework of In-line Phase-contrast Imaging with Ideal Imaging Systems ...............
متن کاملAttainment of <60nm Resolution in Phase-Contrast X-ray Microscopy using an add-on to an SEM
Laboratory-based phase-contrast microscopy is a practical and versatile technique for X-ray imaging and tomography of a wide variety of samples. Using phase-retrieval techniques we can obtain quantitative information about the sample as well as making images easier to interpret. We have demonstrated resolution of <60nm in XuM imaging by coupling phase-retrieval with deconvolution methods for re...
متن کاملX-Ray Phase-Contrast Imaging with Three 2D Gratings
X-ray imaging is of paramount importance for clinical and preclinical imaging but it is fundamentally restricted by the attenuation-based contrast mechanism, which has remained essentially the same since Roentgen's discovery a century ago. Recently, based on the Talbot effect, groundbreaking work was reported using 1D gratings for X-ray phase-contrast imaging with a hospital-grade X-ray tube in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optics express
دوره 19 25 شماره
صفحات -