Simulated optical performance of custom wavefront soft contact lenses for keratoconus.

نویسندگان

  • John de Brabander
  • Nicolas Chateau
  • Gildas Marin
  • Norberto Lopez-Gil
  • Eef Van Der Worp
  • Antonio Benito
چکیده

PURPOSE Outstanding improvements in vision can theoretically be expected using contact lenses that correct monochromatic aberrations of the eye. Imperfections in such correction inherent to contact lenses are lens flexure, translation, rotation, and tear layer effects. The effects of pupil size and accommodation on ocular aberration may cause further difficulties. The purpose of this study was to evaluate whether nonaxisymmetric soft contact lenses could efficiently compensate for higher-order aberrations induced by keratoconus and to what extent rotation and translation of the lens would degrade this perfect correction. METHODS Height topography data of nine moderate to severe keratoconus corneas were obtained using the Maastricht Shape Topographer. Three-dimensional ray tracing was applied to each elevation topography to calculate aberrations in the form of a phase error mapping. The effect of a nonaxisymmetric soft contact lens tailored to the corneal aberrations was simulated by adding an opposite phase error mapping that would theoretically compensate all corneal-induced optical aberrations of the keratoconus eyes. Translation (0.25, 0.5, 0.75, and 1.0 mm) and rotation (2.5 degrees, 5.0 degrees, 7.5 degrees, and 10 degrees ) mismatches were introduced. The modulation transfer function (MTF) of each eye with each displaced correction and with various pupil sizes (3, 5, and 7 mm) was deduced from the residual phase error mapping. A single performance criterion (mtfA) was calculated as the area under the MTF over a limited spatial frequency range (5 to 15 periods per degree). Finally, the ratio (RmtfA) of corrected mtfA over uncorrected mtfA provided an estimate of the global enhancement in contrast sensitivity with the customized lens. RESULTS The contrast improvement ratios RmtfA with perfectly located lenses were for an average pupil size of 4.5 mm between 6.5 and 200. For small translation errors (0.25 mm), RmtfA ranged between 2 and 7. The largest lens translation tested (1 mm) often resulted in poorer performance than without correction (RmtfA <1). More than threefold improvements were achieved with any of the angular errors experimented. RmtfA values showed significant variations for pupil diameters between 3 and 7 mm. CONCLUSIONS Three-dimensional aberration-customized soft contact lenses may drastically improve visual performance in patients with keratoconus. However, such lenses should be well positioned on the cornea. In particular, translation errors should not exceed 0.5 mm. Angular errors appeared to be less critical. It is further questioned whether the visual system is able to adapt to variations in optical performance of the correction in situ due to lens positioning and pupil size.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On-eye performance of custom wavefront-guided soft contact lenses in a habitual soft lens-wearing keratoconic patient.

PURPOSE To assess visual, optical, and fitting characteristics for wavefront-guided soft contact lenses produced for one habitual soft lens-wearing moderate keratoconic eye. METHODS A process for production and evaluation of custom wavefront-guided soft contact lenses was developed. Wavefront aberrations were quantified with the COAS-HD wavefront sensor (Wavefront Sciences); soft contact lens...

متن کامل

The Lower- and Higher-Order Aberrations of the Eye

Keratoconus causes a reduction in the optical quality of the eye as a result of corneal distortion, corneal scarring and higher-order aberrations. The correction of these optical aberrations would significantly improve the visual performance of keratoconic eyes. However the first step would be to measure the optical flaws in keratoconus accurately, which in itself presents a challenge. This pap...

متن کامل

Generation of Higher Order Aberrations with Soft Contact Lens by Excimer Laser Ablation

Although the human eye has a relatively simple optical system, it is not perfect. It has been well known that the human eye suffers from the wavefront aberration that includes both lower (defocus and astigmatism) and higher order aberrations. The lower order aberration has been effectively corrected with conventional ophthalmic lenses such as spectacles and contact lenses. However, it is more c...

متن کامل

Visual Performance and Optical Quality of Standardized Asymmetric Soft Contact Lenses in Patients With Keratoconus.

Purpose To evaluate the visual performance and optical quality of a standardized asymmetric soft contact lens (SCL) used for correction of higher-order aberrations (HOAs) in eyes with keratoconus. Methods We included 30 eyes (26 patients) with keratoconus (average K: 45.7 ± 2.3 diopters [D]). The patients were subjected to corneal tomography, aberrometry, measurements of manifest refraction a...

متن کامل

[Measuring the refractive power of customized soft contact lenses].

PURPOSE Soft contact lenses with spherical base curves have been used for many years. The computation of the refractive powers of these lenses is easy, requiring only that one uses the lens maker equation for thick lenses. Nevertheless, for customized contact lenses, there is yet no reliable method for measuring the higher order optical aberrations. In this study we have developed in the Center...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optometry and vision science : official publication of the American Academy of Optometry

دوره 80 9  شماره 

صفحات  -

تاریخ انتشار 2003