Simple pressure gauge for uranium hexafluoride.
نویسندگان
چکیده
A sensitive detector and pressure gauge for uranium hexafluoride in high-vacuum systems is described. Negative surface ionization of UF(6) occurs on ribbon filaments operated at temperatures too low for electron emission to be significant. The ion current measured on a cylindrical collector surrounding the filament assembly varies regularly with UF(6) pressure below 10(-3) Torr. Different filament materials are considered, including rhenium, thoriated tungsten, and platinum. Rhenium is found to be the most satisfactory material for operation of diode emitters as a pressure gauge. Gauge constants (in A Torr(-1)) are derived from comparing negative surface ionization currents with the response of a capacitance manometer and are shown to be independent of temperature within a reasonable operating range. The effects of exposing the rhenium filament to various gases is considered, and it is shown that brief exposure to acetylene substantially improves the operating characteristics of the gauge.
منابع مشابه
2. Joint Toxic Action Data for the Mixture of Concern and Component Mixtures
Uranium and fluoride are often found in combination in the nuclear power industry, where uranium hexafluoride is used to enrich uranium mixtures to increase the activity. Upon contact with moisture, including moisture in the air, uranium hexafluoride rapidly hydrolyzes to uranyl fluoride (UO2F2) and hydrogen fluoride. As these uranium compounds see heavy industrial use, many of the studies of t...
متن کاملDevelopment of uranium reference particles to support nuclear safeguards
Controlled hydrolysis of certified uranium hexafluoride, carried out in a specifically constructed aerosol chamber, leads to the production of uranyl fluoride particulates which – deposited on a graphite planchet support may be used as a quality control reference material. The particle size and surface distribution depends on several parameters, such as the relative humidity inside the aerosol ...
متن کاملUse of 25% sulfur hexafluoride gas mixture may minimize short-term postoperative hypotony in sutureless 25-gauge pars plana vitrectomy surgery
BACKGROUND The purpose of this study was to compare postoperative intraocular pressures and percentage of vitreous cavity gas fill one day following 25-gauge pars plana vitrectomy with 20% versus 25% sulfur hexafluoride (SF6) gas fill. METHODS This was a retrospective review of 187 consecutive cases of 25-gauge pars plana vitrectomy with complete fluid/gas exchange. The main outcome measures ...
متن کاملGas-Phase Reactions of Bare and Ligated Uranium Ions with Sulfur Hexafluoride
Reactions of bare and ligated uranium ions with sulfur hexafluoride were studied in a quadrupole ion trap mass spectrometer. Bare U+ was found to react rather efficiently with SF6 (k/kADO ∼ 0.4) to produce both UFn (n ) 1, 2, 3, 4) and SFn (n ) 1, 2, 3). Whereas the UF/SF6 reaction rate was essentially the same as that for U/SF6, both UF2 and UF3 were inert; this is attributed to a repulsive in...
متن کاملPreparing a Small Town for a Hazardous Materials Incident: An Examination of Evacuation Routing Algorithms and Plume Models
Evacuation and shelter in place are two common protective action measures during hazardous events that involve the release of hazardous materials. These responses are complex and require advanced planning to determine their appropriateness to reduce human exposure to hazardous materials and minimize related health risks. Evacuation and shelter in place responses were assessed for people in the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 50 12 شماره
صفحات -
تاریخ انتشار 1979