X-ray optics for better diagnostic imaging.

نویسندگان

  • C A MacDonald
  • W M Gibson
  • W W Peppler
چکیده

Polycapillary x-ray optics provide an innovative new way to control x-ray beams. Placing these optics after the object to be imaged provides very efficient rejection of Compton scatter, while allowing image magnification without loss of resolution, image demagnification, or image shaping to match with digital detectors. Measured scatter rejection optics had primary transmissions greater than 50% and scatter transmission of less than 1%. For a 5-cm thick Lucite phantom, this resulted in a contrast enhancement of nearly a factor of two at 20 keV and three at 40 keV. The magnification from the tapered capillary optics improved the MTF at all frequencies out to 1.8 times the original system resolution. Increases below the system resolution are most important because clinically relevant structures generally occupy lower spatial frequencies. Alternatively, placing a collimating optic and diffracting crystal before the patient provides sufficient monochromatic beam intensity for medical imaging. Contrast, resolution, and intensity measurements were performed with both high and low angular acceptance crystals. At 8 keV, contrast enhancement was a factor of 5 relative to the polychromatic case, in good agreement with theoretical values. At 17.5 keV, monochromatic subject contrast was more than a factor of 2 times greater than the conventional polychromatic contrast. An additional factor of two increase in contrast, for a total factor of four, is expected from the removal of scatter in a large beam clinical system. The measured angular resolution after the crystal was 0.4 mrad for a silicon crystal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quality assessment of conventional X-ray diagnostic equipment by measuring X-ray exposure and tube output parameters in Great Khorasan Province, Iran

Introduction: Regular implementation of quality control (QC) program in diagnostic X-ray facilities may affect both image quality and patient radiation dose due to the changes in exposure parameters. Therefore, this study aimed to investigate the status of randomly selected conventional radiographic X-ray devices installed in radiology centers of Great Khorasan Province, Iran, to produce the da...

متن کامل

Imaging cellular architecture with X-rays.

X-ray imaging of biological samples is progressing rapidly. In this paper we review the progress to date in high-resolution imaging of cellular architecture. In particular we survey the progress in soft X-ray tomography and argue that the field is coming of age and that important biological insights are starting to emerge. We then review the new ideas based on coherent diffraction. These method...

متن کامل

Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...

متن کامل

Thoracic Mass Nature Determination; What Modality Is Better in Pediatric Age?

Background The first step in assessing thoracic lesions is chest X-ray, but the optional imaging procedure for the final diagnosis is controversial. We aimed to examine the diagnostic accuracy of imaging modalities in pediatric thoracic masses. <em...

متن کامل

Full-field transmission x-ray imaging with confocal polycapillary x-ray optics.

A transmission x-ray imaging setup based on a confocal combination of a polycapillary focusing x-ray optic followed by a polycapillary collimating x-ray optic was designed and demonstrated to have good resolution, better than the unmagnified pixel size and unlimited by the x-ray tube spot size. This imaging setup has potential application in x-ray imaging for small samples, for example, for his...

متن کامل

Investigation of the Mass Attenuation Coefficient for Composites Containing Nano and Micro-Particles of Copper Oxide against Diagnostic X-ray

Radiation protection and the selection of suitable materials to reduce radiation effects is one of the important branches of medical science and radiation. In this paper, the mass attenuation coefficients, half value layer thicknesses and thicknesses of 0/5 mm lead of polyvinyl chloride (PVC) composites containing Nano and micro-particles of copper oxide are calculated using experimental method...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Technology in cancer research & treatment

دوره 1 2  شماره 

صفحات  -

تاریخ انتشار 2002