Improving Laboratory Results Turnaround Time By Reducing Pre Analytical Phase
نویسندگان
چکیده
Laboratory turnaround time is considered one of the most important indicators of work efficiency in hospitals, physicians always need timely results to take effective clinical decisions especially in the emergency department where these results can guide physicians whether to admit patients to the hospital, discharge them home or do further investigations. A retrospective data analysis study was performed to identify the effects of ER and Lab staff training on new routines for sample collection and transportation on the pre-analytical phase of turnaround time. Renal profile tests requested by the ER and performed in 2013 has been selected as a sample, and data about 7,519 tests were retrieved and analyzed to compare turnaround time intervals before and after implementing new routines. Results showed significant time reduction on "Request to Sample Collection" and "Collection to In Lab Delivery" time intervals with less significant improvement on the analytical phase of the turnaround time.
منابع مشابه
Monitoring of Turnaround time (TAT) in Biochemistry Laboratory of a tertiary care hospital in Punjab
Turnaround time (TAT) is commonly defined as the time from when a test is ordered until the result is reported which includes the preanalytical, analytical and post-analytical time. Increased attention to patient’s needs is demonstrated by efforts to improve the quality of the entire service provided, e. g reduction of laboratory turnaround time (TAT). The availability of the results from a lab...
متن کاملLean six sigma process improvement in specimen receiving to improve stat chemistry turnaround times
Objective: As a consequence of stat turnaround times (TATs) chronically exceeding 60 minutes, our laboratory was facing pressure to divert limited resources toward the implementation of an emergency department satellite laboratory. Peer-reviewed literature in clinical laboratory quality assurance and improvement indicates that between 60-70% of errors occur at the pre-analytical level. Thus...
متن کاملThe Evaluation of Error Types and Turnaround Time of Preanalytical Phase in Biochemistry and Hematology Laboratories
Background& Objective: Each laboratory should determine the type of errors and turnaround time (TAT), especially in the preanalytical phase to report quality and timeliness of the test results. The current study aimed at investigating the common causes of preanalytical errors in biochemistry and hematology laboratories and evaluating the preanalytical ...
متن کاملLaboratory-based clinical audit as a tool for continual improvement: an example from CSF chemistry turnaround time audit in a South-African teaching hospital
INTRODUCTION Timeliness of laboratory results is crucial to patient care and outcome. Monitoring turnaround times (TAT), especially for emergency tests, is important to measure the effectiveness and efficiency of laboratory services. Laboratory-based clinical audits reveal opportunities for improving quality. Our aim was to identify the most critical steps causing a high TAT for cerebrospinal f...
متن کاملDetermination of the Rate and Reasons of Blood Sample Rejection in the Pre-Analytical Phase in Ruhengeri, Rwanda: A Single Center Study
Background and objectives: All three phases of laboratory testing are equally important for improving total quality management, but the pre-analytical phase is the most error-prone. This study aimed to determine the rate and reasons for blood sample rejection in the pre-analytical phase of laboratory testing in a referral hospital in Ruhengeri, Rwanda. Methods: This study was a cross-sectional...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Studies in health technology and informatics
دوره 202 شماره
صفحات -
تاریخ انتشار 2014