Evaluation of Safety and Efficacy of the MaximusTM System for Facial Wrinkles
نویسندگان
چکیده
Introduction: There is a growing demand for non-invasive methods with no down time and minimal risk for facial skin rejuvenation and treatment of wrinkles. The Maximus system, based on TriLipo technology, combines radiofrequency and Dynamic Muscle Activation (DMA). We evaluated the safety and efficacy of the MaximusTM system for the treatment of facial wrinkles. Methods: Twenty women received 8 weekly treatments for facial wrinkles using the Maximus system. Treatment efficacy was assessed by comparing preand post-treatment photographs, assessing skin characteristics using the 3D Visioscan system, assessing skin microtopography using the DUB ultrasonic scanning system, assessing microcirculation conditions of facial skin using Laser Doppler Flowmetry (LDF) and subjective evaluation of skin improvement. Results: No adverse events were observed. Following the treatments, positive changes in skin flakiness (scaliness), roughness, smoothness and wrinkles were demonstrated using Visioscan. A thickening of the epidermal-dermal layer and increased structural homogeneity were observed by ultrasound, hyperechogenicity was increased and areas of hypoechogenicity reduced. Microcirculation was improved, corresponding with a positive trend for improved skin characteristics. Conclusions: The Maximus system powered by the TriLipo technology is a non-invasive, effective, safe, and virtually painless treatment for reduction of wrinkles and facial skin rejuvenation.
منابع مشابه
Evaluation of safety and efficacy of the TriFractional RF technology for treatment of facial wrinkles.
INTRODUCTION Skin resurfacing is an accepted gold standard for the treatment of skin laxity, photodamage, and appearance of visible lines and wrinkles. However, the relatively significant risk and the long downtime associated with whole area resurfacing treatments have led to the introduction of fractional resurfacing lasers and radiofrequency (RF) technologies. This study was performed in orde...
متن کاملComparative clinical assessment of two nasolabial hyaluronic acid fillers: A double-blind, randomized controlled trial
Background: Various fillers have been used for the correction of nasolabial folds. This study investigated the efficacy and safety assessment of two hyaluronic acid (HA) fillers on moderate nasolabial folds. Methods: This study randomized 10 volunteers, aged 35 to 49 years, with moderate nasolabial folds. Volunteers received injections of HA A and HA B gels into the right or left skin folds. Th...
متن کاملEvaluation of safety and efficacy of the TriPollar technology for treatment of wrinkles.
INTRODUCTION Patient demand for non-surgical, non-invasive, and no-downtime wrinkle reduction treatment procedures has grown dramatically over the past decade as new treatments and technologies have been introduced. This study was performed in order to evaluate the safety and efficacy of the TriPollar radiofrequency (RF) technology and intended for wrinkle reduction treatment. METHODS Thirty-...
متن کاملThe Clinical Efficacy And Safety Of Microneedling Fractional Radiofrequency In The Treatment Of Facial Wrinkles: A Multicenter Study With The Infini System In 499 Patients
متن کامل
Evaluation of the efficacy and safety of “Anti-Wrinkle cream” in the treatment of facial skin wrinkles: A prospective, open, phase III clinical trial
Aging of the skin is the result of continuous "wear and tear" processes. Chronological skin aging is a universal and inevitable process, while in contrast, photoaging results from the UV rays of sunlight, and the damage becomes apparent in sun-exposed skin. The “AntiWrinkle cream” is a polyherbal formulation recommended for the management of skin wrink the efficacy and safety of the “Anti-Wrink...
متن کامل