Awake Microlaparoscopy with the Insuflow® Device
نویسنده
چکیده
BACKGROUND AND OBJECTIVES Patients undergoing laparoscopy often complain of shoulder pain, shivering, or both following laparoscopy. An increase in awake microlaparoscopic procedures has been reported. The objective of this study was to investigate the usefulness of heating and humidifying the carbon dioxide gas for the pneumoperitoneum with the Insuflow device (Lexion Medical, St. Paul, Minnesota) during awake microlaparoscopic procedures. METHODS Awake microlaparoscopy was performed with the Insuflow device for heating and humidifying the carbon dioxide for the pneumoperitoneum. RESULTS The incidence of transient shoulder pain in the Insuflow group was 5% compared with 40% in the dry carbon dioxide group. No patient in the Insuflow group complained of shivering, whereas 55% in the control group had shivering. Fogging of the microlaparoscope lens was decreased in the Insuflow group. CONCLUSIONS Heating and humidifying the carbon dioxide gas produced fewer patient complaints of shoulder pain and shivering and decreased fogging of the microlaparoscope lens compared with procedures done with dry carbon dioxide during awake microlaparoscopic procedures.
منابع مشابه
Complications of Microlaparoscopy and Awake Laparoscopy
Complications of laparoscopy are categorized into trocar insertion complications, complications resulting from image quality, and complications resulting from instrumentation. Microlaparoscopy also has similar complications and additional complications when being performed in the awake patient. Each of these complications is reviewed as they apply to microlaparoscopy. The results reveal that th...
متن کاملReduction of Laparoscopic-Induced Hypothermia, Postoperative Pain and Recovery Room Length of Stay by Pre-Conditioning Gas with the Insuflow® Device: A Prospective Randomized Controlled Multi-Center Study
OBJECTIVE To assess the efficacy and safety of Insuflow (Georgia BioMedical, Inc.) filter heater hydrator device in reducing the incidence, severity and extent of hypothermia, length of recovery room stay and postoperative pain at the time of laparoscopy. DESIGN Prospective, randomized, blinded, controlled multi-center study. Patients underwent gynecologic procedures via laparoscopy; surgeons...
متن کاملA Simple Solution to Lens Fogging during Robotic and Laparoscopic Surgery
We have routinely used FRED antifog solution (US Surgical, North Haven, CT), which consists of less than 15% isopropyl alcohol, 2% surfactant, and more than 85% water, during laparoscopic procedures.1 We also use the Insuflow (Lexion Medical, St. Paul, MN) device. Insuflow is a single-use device that attaches to the outlet port of an insufflator and is designed to warm and humidify the gas stre...
متن کاملTranscervical Migration of an Essure® Coil
Introduction: Essure® device malposition is a rare, but clinically significant complication, for which management is idiosyncratic. This case report describes an unusual example of Essure® migration in order to clarify reasonable management options. Case Presentation: A 50-year old G4P2022 underwent hysteroscopi...
متن کاملAppendectomy under local anaesthesia following conscious pain mapping with microlaparoscopy.
The appendix is an under-appreciated source of chronic pelvic pain. Laparoscopic evaluation of the appendix is limited without intra-operative patient feedback on the presence and absence of pain. New techniques using local anaesthesia with conscious sedation have enabled us to perform operative laparoscopic surgery while the patient is awake. We report the first two cases of microlaparoscopic ...
متن کامل