Impedance Control of Two d.o.f. CPM Device for Elbow Joint

نویسندگان

  • Nobutomo Matsunaga
  • Shota Miyaguchi
  • Hiroshi Okajima
  • Shigeyasu Kawaji
چکیده

Recently, new technology that supports human will be an emergent issue as population ages and birthrate declines. As human having a lot of joints utilizes many degrees of freedom (d.o.f.) for living and working, reduction or loss of d.o.f. will deteriorate the quality of life. So, it will be important to recover joint functions immediately after injury or operation. Accordingly, many studies have been performed on the development and application of orthopedic treatment or rehabilitation training devices (Furusho et al., 2005; Duong et al., 2005; Mavroidis et al., 2005; Hogan et al., 2006). In the tendency, continuous passive motion (CPM) was proposed as an orthopaedic treatment and a physiotherapy method that promotes recovery from the injuries after surgery of joints (Salter et al., 1960). The CPM is intended to accelerate the regeneration of periarticular tissues, to prevent contracture, and to correct range of motion (ROM) (Salter, 1993), and is more effective than conventional treatment method with casts (Salter, 1993; O'Driscoll et al., 2000). There are many works on the CPM devices for the lower limbs. Particularly, the CPM devices for the knee joint have been widely used. It was reported that these devices induce quick recovery and improve the joint ROM more effectively (Tanaka, 1998; Sakaki et al., 2000; Akdogan et al., 2006). The knee joint has a simple hinged joint, which is the same structure as the CPM devices for the knee joint, so that the CPM devices can perform effective CPM by easy setting. On the other hand, there are few researches about CPM devices for the upper limbs because of the musculoskeletal complexity. Most conventional CPM devices for the elbow joint have only one d.o.f., and perform the flex-/extension with fixed forearm to avoid the complex setting of the device (Kawaji, 2006). The human’s elbow joint, which consists of a radius, ulna, humerus and biological tissues, has complex structure, and is structurally different from the conventional CPM devices for the elbow. This difference causes some problems such as fluctuation of rotation center of the flex-/extension, excessive reaction force due to the inappropriate pose of the forearm, etc. For the former, Usui et. al. have proposed an algorithm that compensates the fluctuation of the rotation center while the rehabilitation(Usui et al., 2004). But, for the latter there are few researches about the variation of the reaction force due to the forearm position i.e., the pro/supination. 13

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impedance Control of Two d.o.f CPM Device for Upper Limb Disorders

Continuous passive motion (CPM) is an orthopedic treatment or a physiotherapy and is tried to apply after surgery for the injured radial collateral ligament (RCL) in the elbow joint. After the surgery, the reaction force at hand of the patient increases due to an increase of the joint stiffness and may be excessively large. For this, it is effective to reduce the excessive reaction force by con...

متن کامل

Kinematics and Dynamic Modelling of the Human Shoulder

This paper deals with kinematics and dynamics of the human shoulder in order to obtain the workspace related to the reachability of the wrist and applications to determine load for the wheelchair. The model contains six revolute degrees of freedom (D.O.F), two in costoclavicular and three in the shoulder joint and one in the elbow joint, while a six D.O.F model was developed according to given ...

متن کامل

Elbow CPM Following a Stable Intra-Articular Fracture

CPM after a stable fracture has been used extensively in the elbow.9,19,20,21,22,28,30,43,46,48 The initial goal of therapy following a stable fracture is to maintain the range-of-motion. If passive motion is not started within the first 48 hours the prognosis for improvement is significantly diminished.10 O’Driscoll and Giori36 have demonstrated that CPM immediately following a surgical proced...

متن کامل

Early Regain of Function and Proprioceptive Improvement Following Knee Arthroplasty

Background: Techniques that allow early muscle activation, such as closed kinetic chain (CKC) and open kineticchain (OKC) exercises, may play a beneficial role in the early rehabilitation of the reconstructed knee. However,current rehabilitation regimens have not been shown to reverse post-operative quadriceps activation failureand weakness. To investigate whether patients who use a continuous ...

متن کامل

Mechanical Simulation of the Extension and Flexion of the Elbow Joint in Rehabilitation

Objective: The goal of the present study was to improve the extension and flexion of the elbow joint for rehabilitation purposes, in terms of energy dissipation and of injuries caused by stress imposed on connective tissue by exercise equipments during force transfer , by investigation of viscoelastic property variations during change in speed of motion. Materials & Methods: A sample of five...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JRM

دوره 26  شماره 

صفحات  -

تاریخ انتشار 2014