Hydrogen permeability of Pd-Ag membrane modules with porous stainless steel substrates

نویسندگان

  • Donglai Xie
  • Jinfeng Yu
  • Fang Wang
  • Ning Zhang
  • Weixing Wang
  • Hao Yu
  • Feng Peng
چکیده

Palladium-based membranes are attractive for their nearly perfect permselectivity to hydrogen. Membrane modules, consisting of a membrane foil, porous stainless steel substrate, test frame and flange were assembled and tested in an electrically heated vessel. Instantaneous hydrogen permeation flux was measured. Influences of operation conditions on the membrane performance were examined. Microstructure and morphology of the membrane surface and the cross-sectional surface of the substrate and membrane foil were characterized by scanning electron microscopy. It was observed that for an operation temperature higher than 755 K, the hydrogen permeation flux through the membrane module with 0.2 mm grade porous 316L stainless steel substrate decayed continuously due to the inter-metallic diffusion between the membrane and the substrate. For a temperature of around 869 Ke943 K, a stable hydrogen permeation flux through the membrane module with 0.5 mm grade stainless steel substrate was observed. Pretreatment of the 0.5 mm grade substrate with polishing and etching helped to smooth the membrane foil surface. However, it changed the surface structure of the material and led to a decrease in hydrogen permeability. Under the conditions investigated, the permeation factor of the module increased by raising the hydrogen pressure in the vessel side and decreasing the membrane module temperature. By decreasing the hydrogen exit partial pressure by sweep gas, the membrane module permeation flux increased, while the permeation factor decreased. a 2010 Professor T. Nejat Veziroglu. Published by Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of thermodynamic parameters of hydrogen permeation of palladium membrane for considering the effect of stainless steel support

A palladium composite membrane was prepared by electroless plating on oxidized porous stainless steel support (ox-PSS). Hydrogen permeation flux through this composite membrane was measured in the temperature range of 574-674K and the pressure difference of two sides of membrane up to 90kPa. A simplified resistance model was employed to analyze the permeation behavior of hydrogen through Pd/ox-...

متن کامل

Developing of Ethylene Glycol as a New Reducing Agent for Preparation of Pd-Ag/PSS Composite Membrane for Hydrogen Separation

In the present work, for the first time, a palladium-silver membrane has been prepared by electroless plating on the surface of a porous stainless steel disk by using ethylene glycol as a new reducing agent and polyol process. The reducing action of ethylene-glycol in the presence of PVP as a protecting surface agent produces a membrane with finely divided powder and nano-sized pores. Furthermo...

متن کامل

Novel Electroless Plating of Ruthenium for Fabrication of Palladium-Ruthenium Composite Membrane on PSS Substrate and Its Characterization

This paper focused on a novel method of electroless plating ruthenium (Ru) on solid or porous substrates like porous stainless steel (PSS) discs or ceramic tubes. A novel complexing plating bath of Ru was developed. It is proven that Ru can be deposited directly on these substrates by the bath at a temperature of 328 K and strong alkaline environment. TGA, SEM, EDX and XRD confirmed the success...

متن کامل

Performance and Long-Term Stability of Pd/PSS and Pd/Al2O3 Membranes for Hydrogen Separation

The present work is focused on the investigation of the performance and long-term stability of two composite palladium membranes under different operating conditions. One membrane (Pd/porous stainless steel (PSS)) is characterized by a ~10 µm-thick palladium layer on a porous stainless steel substrate, which is pretreated by means of surface modification and oxidation; the other membrane (Pd/Al...

متن کامل

Determination of the effective thickness of a porous electrode in a flow-through reactor; effect of the specific surface area of stainless steel fibres, used as a porous cathode, during the deposition of Ag(I) ions

This study discusses the use of potential distribution analysis during the deposition of metal ions, at limiting current conditions and determines the optimum electrode thickness at which no hydrogen evolution occurs. The potential distribution studies were carried out on stainless-steel fibres of three different surface areas. The fibres were used as cathodic porous electrodes during the depos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011