Computational fluid dynamic analysis to prevent aortic root and valve clots during left ventricular assist device support.
نویسنده
چکیده
Aortic root and valve clots are rare but well described in patients on maximal left ventricular assist device (LVAD) support. We performed a theoretical analysis using computational fluid dynamic analyses in two dimensions to try and ascertain if inflow cannula design/orientation/placement affect aortic root flow dynamics. Two-dimensional computational fluid dynamics using easy CFD-G was performed. The effect of a curved inflow cannula, a straight cannula, and one with a hole in the outer curve was analyzed. In addition, the effect of inflow conduit angulation on the ascending aorta was studied. Computational fluid dynamic (CFD) analysis predicts that stagnant blood exists in the aortic root when little or no cardiac ejection is taking place. Coronary flow is too small to affect the root flow streamlines. A hole on the root side of a curved inflow aortic cannula increases the flow in the aortic root and may decrease the incidence of root and valve thrombosis. The angle of the inflow conduit attachment to the ascending aorta was also found to be crucial with regard to aortic root blood stasis. In addition, a baffle at the tip of the inflow cannula may prove to be beneficial. Theoretical analysis using the technique of CFD predicts that inflow cannula position and design may affect the incidence of aortic root thrombosis during LVAD support when minimal cardiac ejection is occurring.
منابع مشابه
Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)
Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...
متن کاملComputational Analysis of Pumping Efficacy of a Left Ventricular Assist Device according to Cannulation Site in Heart Failure with Valvular Regurgitation
Mitral valve regurgitation (MR) causes blood to flow in two directions during contraction of the left ventricle (LV), that is, forward into the aorta and backward into the left atrium (LA). In aortic valve regurgitation (AR), leakage occurs from the aorta into the LV during diastole. Our objective is to analyze the contribution of a left ventricular assist device (LVAD) to MR and AR for the fol...
متن کاملOpening of native aortic valve accomplished after left ventricular assist device implantation in patients with insufficient preoperative Beta-blocker treatment.
Although we recently demonstrated that opening of a native aortic valve (AV) after left ventricular assist device (LVAD) implantation is a sufficient condition to prevent development of aortic insufficiency (AI), its preoperative predictors remain unknown. Data were obtained from 58 patients who had been treated with continuous flow LVAD for ≥ 6 months at our institute between 2006 and 2014. Op...
متن کاملBicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva
Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...
متن کاملDesign an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of extra-corporeal technology
دوره 44 4 شماره
صفحات -
تاریخ انتشار 2012