Defocus test and defocus correction in full-field optical coherence tomography.

نویسندگان

  • S Labiau
  • G David
  • S Gigan
  • A C Boccara
چکیده

We report experimental evidence and correction of defocus in full-field optical coherence tomography of biological samples owing to mismatch of the refractive index of biological tissues and water. Via a metric based on the image quality, we demonstrate that we are able to compensate this index-induced defocus and to recover a sharp image in depth.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical Defocus Rapidly Changes Choroidal Thickness in Schoolchildren

The current study aimed to examine the short-term choroidal response to optical defocus in schoolchildren. Myopic schoolchildren aged 8-16 were randomly allocated to control group (CG), myopic defocus group (MDG) and hyperopic defocus group (HDG) (n = 17 per group). Children in MDG and HDG received additional +3D and -3D lenses, respectively, to their full corrections on the right eyes. Full co...

متن کامل

Inverse scattering for frequency-scanned full-field optical coherence tomography.

Full-field optical coherence tomography (OCT) is able to image an entire en face plane of scatterers simultaneously, but typically the focus is scanned through the volume to acquire three-dimensional structure. By solving the inverse scattering problem for full-field OCT, we show it is possible to computationally reconstruct a three-dimensional volume while the focus is fixed at one plane insid...

متن کامل

Brain refractive index measured in vivo with high-NA defocus-corrected full-field OCT and consequences for two-photon microscopy.

Two-photon laser scanning microscopy (2PLSM) is an important tool for in vivo tissue imaging with sub-cellular resolution, but the penetration depth of current systems is potentially limited by sample-induced optical aberrations. To quantify these, we measured the refractive index n' in the somatosensory cortex of 7 rats in vivo using defocus optimization in full-field optical coherence tomogra...

متن کامل

Effect of Refractive Correction Error on Retinal Nerve Fiber Layer Thickness: A Spectralis Optical Coherence Tomography Study

BACKGROUND Identifying and assessing retinal nerve fiber layer defects are important for diagnosing and managing glaucoma. We aimed to investigate the effect of refractive correction error on retinal nerve fiber layer (RNFL) thickness measured with Spectralis spectral-domain optical coherence tomography (SD-OCT). MATERIAL AND METHODS We included 68 participants: 32 healthy (normal) and 36 glauc...

متن کامل

Influence of optical defocus on peripheral vision.

PURPOSE Peripheral optical corrections are often thought to give few visual benefits beyond improved detection acuity. However, patients with central visual field loss seem to benefit from peripheral correction, and animal studies suggest a role for peripheral vision in the development of myopia. This study was conducted to bridge this gap by systematically studying the sensitivity to optical d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 34 10  شماره 

صفحات  -

تاریخ انتشار 2009