Trigeminal ganglion and its divisions: detailed anatomic MR imaging with contrast-enhanced 3D constructive interference in the steady state sequences.

نویسندگان

  • Indra Yousry
  • Bernhard Moriggl
  • Urs D Schmid
  • Thomas P Naidich
  • Tarek A Yousry
چکیده

BACKGROUND AND PURPOSE Visualization of the trigeminal system is important for imaging diagnosis but technically challenging. We assessed how well the trigeminal ganglion, its rootlets, and its branches (V1, V2, and V3) are depicted on three high-resolution pulse sequences. METHODS Twenty-two patients (44 sides) underwent nonenhanced 3D constructive interference in the steady state (CISS) MR imaging. Two of these patients and another 20 (44 sides) also underwent contrast-enhanced 3D CISS and contrast-enhanced 3D time-of-flight (TOF) MR angiographic (MRA) imaging. Appearances of the ganglion, sinus ganglii, ganglion lip, and sensory and motor rootlets in the Meckel cave were assessed. RESULTS The trigeminal ganglion was shown on enhanced 3D CISS images in all cases, on nonenhanced 3D CISS images in 77.3%, and on enhanced 3D TOF MRA images in 92.9%. Sinus ganglia and lips were demonstrated on 98% of enhanced 3D CISS images. Sensory rootlets were depicted with all 3D CISS sequences but no 3D TOF sequences. V1, V2, and V3 were displayed with all enhanced 3D TOF MRA sequences, 79.5-100% of enhanced 3D CISS sequences, and 0-50% of nonenhanced 3D CISS sequences. CONCLUSION The enhanced 3D CISS sequence was best for displaying the trigeminal ganglion, sinus ganglii, and sinus lips, whereas the enhanced 3D TOF sequence best displayed the emerging V1, V2, and V3 roots. The enhanced 3D CISS sequence was most useful. Complete MR imaging evaluation of the trigeminal ganglion and roots is best performed by using enhanced 3D CISS and enhanced 3D TOF MRA sequences.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Identification of the normal jugular foramen and lower cranial nerve anatomy: contrast-enhanced 3D fast imaging employing steady-state acquisition MR imaging.

SUMMARY Conventional imaging protocols are unable to visualize the intraforaminal/canalicular segments of the lower cranial nerves (IX-XII). On the basis of previous successful demonstration of individual cranial nerves within the cavernous sinus by constructive interference in steady-state MR imaging, we describe the use of contrast-enhanced 3D fast imaging employing steady-state acquisition M...

متن کامل

Normal cranial nerves in the cavernous sinuses: contrast-enhanced three-dimensional constructive interference in the steady state MR imaging.

BACKGROUND AND PURPOSE Three-dimensional (3D) constructive interference in steady state (CISS) MR imaging is useful for demonstrating cranial nerves (CNs) in the cistern. The purpose of this study was to evaluate normal CNs III, IV, V1, V2, and VI in the cavernous sinuses by using contrast-enhanced, three-dimensional (3D), Fourier transformation CISS MR imaging. METHODS In 76 normal cavernous...

متن کامل

Appearance of Normal Cranial Nerves on Steady - State Free Pre - cession

As radiologic imaging technology improves and more intricate details of the anatomy can be evaluated, images provide more precise diagnostic information and allow better localization of abnormalities. For example, standard T2-weighted magnetic resonance (MR) imaging sequences adequately depicted only the larger cranial nerves, whereas current steady-state free precession (SSFP) sequences are ca...

متن کامل

High-resolution 3D-constructive interference in steady-state MR imaging and 3D time-of-flight MR angiography in neurovascular compression: a comparison between 3T and 1.5T.

BACKGROUND AND PURPOSE High-resolution MR imaging is useful for diagnosis and preoperative planning in patients with NVC. Because high-field MR imaging promises higher SNR and resolution, the aim of this study was to determine the value of high-resolution 3D-CISS and 3D-TOF MRA at 3T compared with 1.5T in patients with NVC. MATERIALS AND METHODS Forty-seven patients with NVC, trigeminal neura...

متن کامل

Improved detection of intraventricular cysticercal cysts with the use of three-dimensional constructive interference in steady state MR sequences.

BACKGROUND AND PURPOSE Before the advent of MR imaging, intraventricular cysts were difficult to diagnose noninvasively. Among the invasive procedures used were contrast ventriculography and CT ventriculography. MR imaging, with its multiplanar imaging capabilities, excellent depiction of tissue contrast, and versatile parameters, is an important tool in the assessment of intraventricular cysti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 26 5  شماره 

صفحات  -

تاریخ انتشار 2005