Evaluation of antivibration glove test protocols associated with the revision of ISO 10819.

نویسندگان

  • Douglas D Reynolds
  • Eric Wolf
چکیده

Effects of modifying the palm adapter geometry on ISO 10819 antivibration glove test results were investigated. 30 rigid acrylic adapters were designed, fabricated, and evaluated. The length of the adapters that met ISO 10819 requirements covered 70-80% of the width of the palm. The upper curvatures of the adaptors were greater than or equal to the radius specified in ISO 10819:1996. Glove vibration transmissibility tests were conducted using a constant velocity vibration input with a value of 0.01 m/s in each third octave frequency band from 16-1,600 Hz (F spectrum). Glove vibration transmissibility results obtained using the M (16-400 Hz) and H (100-1,600 Hz) spectra specified in ISO 10819:1996 were compared to similar results using the constant velocity spectrum. The results obtained from the constant velocity spectrum, when divided into the M and H frequency ranges, were nearly the same as those obtained from the ISO 10819 M and H spectra. Test subject training was required to ensure reliable glove vibration transmissibility results. The measured transmissibility values obtained with the M, H, and F spectra were all higher at the beginning of the test program. The transmissibility values decreased and approached lower limiting values as the test subjects became more experienced.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessing the influence of antivibration glove on digital vascular responses to acute hand-arm vibration.

This study was designed to assess the influence of an antivibration glove on digital vascular responses in healthy subjects exposed to short-term grasping of a vibrating handle. To measure finger blood flow (FBF) and finger skin temperature (FST) once at the end of every min, a blood flowmeter sensor was attached to the dorsum and a thermistor sensor was attached to the medial surface of the su...

متن کامل

A method for reducing adaptor misalignment when testing gloves using ISO 10819.

OBJECTIVES International standard ISO 10819 was established in order to quantify the vibration attenuation characteristics of anti-vibration gloves. One problem that exists with the standard is possible misalignment of the palm adaptor that is placed underneath the test glove. If the adaptor becomes misaligned, the measured glove transmissibility will be lower than the actual value. A tri-axial...

متن کامل

Dynamic behavior and damping capacity of auxetic foam pads

A novel set of auxetic (negative Poisson's ratio) open cell polyurethane foam has been developed and tested under dynamic loading conditions to assess the viscoelastic response under white noise random excitation and compressive cycling. Foam pads normalized to standard ISO 13753 have been tested at room temperature and frequency bandwidth 10-500 Hz to assess transmissibility characteristics fo...

متن کامل

Evaluation of various characteristics of Plastalgin alginate according to International ISO Standards and ADA specifications

Evaluation of various characteristics of Plastalgin alginate according to International ISO Standards and ADA specifications Dr. A. Monzavi* - Dr. GH. Omati Shabestari** - Dr. S. Shahabi*** - Dr. F. Hajloo**** *- Associate Professor of Removable Prosthodontics Dept. - Faculty of Dentistry – Tehran University of Medical Sciences. **- Assistant Professor of Removable Prosthodontics Dept. Faculty ...

متن کامل

Exploration of the Customized Fixtures for the Evaluation of Three-point Bending Strength of Dental Resin Composites

Introduction: This study aimed to devise customized fixtures for the evaluation of three-point bending strength (TPBS) of resin-based dental composites (RBCs). Materials and Methods: A cube-shaped jig made out of wood with dimensions of 105×105×101 mm was prepared in this study. A 20-mm-diameter hole was made in the center of the wooden jig. In addition, a stai...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Industrial health

دوره 43 3  شماره 

صفحات  -

تاریخ انتشار 2005