Discrepancies between arterial oxygen saturation and functional oxygen saturation measured with pulse oximetry in very preterm infants.

نویسندگان

  • Rhonda J Rosychuk
  • Ann Hudson-Mason
  • Dianne Eklund
  • Thierry Lacaze-Masmonteil
چکیده

BACKGROUND Discrepancies between pulse oximetry saturation (SpO(2)) and arterial saturation (SaO(2)) at low blood oxygenation values have been previously reported with significant variations among instruments and studies. Whether pulse oximeters that attenuate motion artifact are less prone to such discrepancies is not well known. OBJECTIVE To prospectively assess the agreement of the Masimo V4 pulse oximeter within the critical 85-95% SpO(2) target range. PATIENTS AND METHODS For all consecutive babies with gestational age <33 weeks, postnatal age <7 days, and an umbilical arterial line, SpO(2) was measured continuously and SaO(2) analyzed on an as-needed basis. Bland-Altman techniques provided estimates of the difference (D = SaO(2) - SpO(2)), standard deviation (SD), and 95% limits of agreement (D ± 2*SD). RESULTS There were 1,032 measurements (114 babies) with SpO(2) between 85 and 95%. The 95% limits of agreement were -2.0 ± 5.8, -2.4 ± 9.2, and -1.9 ± 5.3 in the SpO(2) categories 85-95, 85-89, and 91-95%, respectively. For the SpO(2) categories 85-89% and 91-95%, only 52% (53/101) and 59% (523/886) of SpO(2) values, respectively, corresponded to the analogous SaO(2) categories. In the 85-89% SpO(2) category, SaO(2) was lower than 85% in 39 of the 101 (39%) measurements. CONCLUSION SaO(2) was lower on average than SpO(2) with an increased bias at lower saturation. The -2.4 ± 9.2 95% limits of agreement for SaO(2) - SpO(2) in the 85-89% SpO(2) category suggest that SpO(2) and SaO(2) are not interchangeable and intermittent SaO(2) assessments are warranted when the targeted SpO(2) is within this range.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulse oximetry in preterm infants.

One hundred and twenty five measurements of arterial oxygen saturation (Stcao2) obtained with a transcutaneous pulse oximeter were compared with direct arterial oxygen tension (Pao2) in 13 preterm infants with predominantly fetal haemoglobin. Stcao2 of 86-92% corresponded to Pao2 of 5-13 kPa. Stcao2 above 92%, however, was sometimes associated with Pao2 above 13 kPa.

متن کامل

Effect of Different Positions on Arterial Oxygen Saturation during Enteral Feeding of Preterm Infants Admitted to Neonatal Intensive Care Units

Background: This study aimed to determine the effects of various positions on the arterial oxygen saturation during enteral feeding of preterm infants admitted to Neonatal Intensive Care Units (NICUs). It is assumed that different body positions influence arterial oxygen saturation during enteral feeding.Methods: This crossover clinical trial included 88 infants. The inclusion criteria we...

متن کامل

Correlation between Pulse Oximetry Oxygen Saturation (SpO2) and Measured Arterial Oxygen Saturation (SaO 2 ) and Arterial Oxygen Tension (PaOz) in Neonates

=Abstract=Pulse oximetry has recently been introduced as a method for continuous and non-invasive transcutaneous monitoring of arterial oxygen saturation in neonates. The purpose of our study was to determine the reliability, accuracy, and practicability of pulse oximetry for monitoring arterial oxygenation in sick newborn infants. Pulse oximetry oxygen saturation values (SpO2) were compared wi...

متن کامل

High or low oxygen saturation and severe retinopathy of prematurity: a meta-analysis.

CONTEXT Low oxygen saturation appears to decrease the risk of severe retinopathy of prematurity (ROP) in preterm newborns when administered during the first few weeks after birth. High oxygen saturation seems to reduce the risk at later postmenstrual ages (PMAs). However, previous clinical studies are not conclusive individually. OBJECTIVE To perform a systematic review and meta-analysis to r...

متن کامل

Resuscitation of very preterm infants with 30% vs. 65% oxygen at birth: study protocol for a randomized controlled trial

BACKGROUND Resuscitation at birth with 100% oxygen is known to increase the oxidative burden with concomitant deleterious effects. Although fractions of inspired oxygen (FiO₂) < 100% are widely used in preterm infants, starting resuscitation at a (too) low FiO₂ may result in hypoxia. The objective of this study is to compare the safety and efficacy of resuscitating very preterm infants with an ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Neonatology

دوره 101 1  شماره 

صفحات  -

تاریخ انتشار 2012