Effects of intra-aortic balloon counterpulsation on cardiac performance, oxygen consumption, and coronary blood flow in dogs.

نویسندگان

  • W J Powell
  • W M Daggett
  • A E Magro
  • J A Bianco
  • M J Buckley
  • C A Sanders
  • A R Kantrowitz
  • W G Austen
چکیده

The effect of intra-aortic counterpulsation (IACP) with a balloon upon myocardial oxygen consumption (MVo2), coronaiy blood flow (TCF), and left ventricular performance was studied in 23 anesthetized canine right heart bypass preparations at constant heart rate and cardiac output. In nonhypotensive, nonTCF-limited preparations, IACP produced a fall in left ventricular peak systolic pressure (LVP) and a decrease in MVo2 ( — 1-1 ± 0.2 (SE) ml/min/100 g LV). In these animals there was little steady state change in TCF (—5.6 ±5.9 ml/min), secondary to autoregulation by the coronary vascular bed. Left ventricular end-diastolic pressure (LVEDP) fell if elevated but exhibited little change if initially normal. However, in hypotensive preparations, in which left ventricular performance was substantially limited by a decreased TCF, IACP produced a striking increase in TCF (+40.9 ± 8.6 ml/min) accompanied by an increase in MVo2 (+1.2 ±0.3 ml/min/100 g LV). Elevated LVEDPs fell substantially toward normal. Directionally similar changes in LVEDP could be produced by increasing TCF alone in the absence of balloon pumping. When TCF was maintained constant in the hypotensive, TCF-limited preparation, IACP produced a fall in peak LVP and LVEDP. These data document two effects of intra-aortic balloon counterpulsation upon cardiac dynamics: (1) IACP can decrease left ventricular peak systolic pressure and LVEDP independent of changes in coronary flow; (2) a major effect of IACP in the hypotensive, failing, TCF-limited preparation is to improve cardiac performance by increasing TCF with an associated increase in MVo2. ADDITIONAL

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

2-D ECHO IN EXPERIMENTAL CORONARY STENOSISIPandian and Kerber

(with carbon dioxide) in the aortaa mechanical assistance to the failing ciruclation. Am Heart J 63: 669, 1962 24. Braunwald E, Covell JW, Moroko PR, Ross J: Effects of drugs and of counterpulsation on myocardial oxygen consumption: observations on the ischemic heart. Circulation 40 (suppl IV): IV-220, 1969 25. Powell WJ, Daggett WM, Magro AE, Bianco JA, Buckley MJ, Sanders CA, Kantrowitz AR, A...

متن کامل

The Effect of Intraaortic Balloon Counterpulsation

required for relief of myocardial ischemia. IABP decreased the rate7pressure product and aortic enddiastoliczpressure, and the peak systolic aortic pressure and regional myocardial oxygen consumption declined inall but one patient. Peak and mean aortic diastolic pressures increased. Changes in regional coronary blood flow paralleled changes in peak systolic aortic pressure (r = 0.92, p < 0.007)...

متن کامل

The Influence of Combined Intra-aortic Balloon Counterpulsation and Hyperosmotic Mannitol on Regional Myocardial Blood Flow in Ischemic Myocardium in the Dog

We investigated the combined effectiveness of intraaortic ballooon counterpulsation and hyperosmotic mannitol (25%) on regional myocardial blood flow during acute coronary insufficiency. Cardiac output and paced heart rate were held constant in chloraloseanesthetized dogs during right heart bypass. Acute coronary insufficiency was produced by ligation of the proximal left anterior descending co...

متن کامل

The influence of combined intra-aortic balloon counterpulsation and hyperosomotic mannitol on regional myocardial blood flow in ischemic myocardium in the dog.

We investigated the combined effectiveness of intra-aortic balloon counterpulsation and hyperosmotic mannitol (25%) on regional myocardial blood flow during acute coronary insufficiency. Cardiac output and paced heart rate were held constant in chloralose-anesthetized dogs during right heart bypass. Acute coronary insufficiency was produced by ligation of the proximal left anterior descending c...

متن کامل

Augmentation of regional coronary blood flow by intra-aortic balloon counterpulsation in patients with unstable angina.

Intra-aortic balloon counterpulsation is capable of reducing afterload in patients with unstable angina. Whether it is also capable of augmenting coronary blood flow to poststenotic myocardium is controversial. We studied seven patients receiving maximal drug therapy and requiring balloon pumping for unstable angina as balloon volume and assist ratio were altered. All patients had greater than ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 26 6  شماره 

صفحات  -

تاریخ انتشار 1970