Mechanical insufflation-exsufflation in prevention of post-extubation acute respiratory failure: most welcome but must be used cautiously in critically ill patients

نویسندگان

  • Antonio M Esquinas Rodriguez
  • Egbert Pravinkumar
چکیده

a study published in the previous issue of Critical Care, Gonçalves and colleagues [1] observed a 33% reduction in re-intubation rate in the study group, due to eff ective management of bronchial secretions. Current evidence favors early implementation of noninvasive mechanical ventilation (NIV) in the post-extubation period to reduce re-intubation, especially in patients with hypercapnic respiratory failure [2-4]. However, some important practical issues need to be considered before the use of mechanical insuffl ation-exsufl ation (MI-E) in the post-extubation period can be generalized, especially in patients needing NIV: (a) MI-E application requires that the NIV mask be disconnected, resulting in positive pressure loss, alveolar collapse, and desaturation. (b) MI-E devices do not have entrained oxygen. Hence, any rapid desaturation episode will require immediate reconnection to NIV. (c) Assessment of the eff ective management of bronchial secretions can prove diffi cult because of the lack of an objective or specifi c scoring system. (d) In some situations requiring several MI-E sessions, frequent disconnection from NIV can lead to prolonged use of post-extubation NIV. (e) MI-E may be diffi cult to perform or may lead to poor compliance in cases of unplanned extubation, moderate to severe hypoxemic acute respiratory failure (ARF) after extubation, agitation/anxiety, and tachypnea. (f) Th e eff ectiveness of MI-E should be studied beyond 48 hours, as late-onset extubation failures and post-extubation NIV failures are due mostly to ineff ective secretion clearance [5]. In conclusion, we believe that this original study could have an impact on the management and prevention of post-extubation ARF in a select group of patients. However, owing to the above-mentioned reasons, the use of MI-E cannot be generalized to all patient populations. Competing interests The authors declare that they have no competing interests. References 1. Gonçalves MR, Honrado T, Winck JC, Paiva JA: Eff ects of mechanical insuffl ation-exsuffl ation in preventing respiratory failure after extubation: a randomized controlled trial. A: Early noninvasive ventilation averts extubation failure in patients at risk: a randomized trial. Noninvasive positive-pressure ventilation for postextubation respiratory distress: a randomized controlled trial. Noninvasive positive-pressure ventilation for respiratory failure after extubation. Predictors of failure of noninvasive positive pressure ventilation in patients with acute hypoxemic respiratory failure: a multi-center study. Mechanical insuffl ation-exsuffl ation in prevention of post-extubation acute respiratory failure: most welcome but must be used cautiously in critically ill patients insuffl ation-exsuffl ation in prevention of post-extubation acute respiratory failure: most welcome …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of mechanical insufflation-exsufflation in preventing respiratory failure after extubation: a randomized controlled trial

INTRODUCTION Weaning protocols that include noninvasive ventilation (NIV) decrease re-intubation rates and ICU length of stay. However, impaired airway clearance is associated with NIV failure. Mechanical insufflation-exsufflation (MI-E) has been proven to be very effective in patients receiving NIV. We aimed to assess the efficacy of MI-E as part of an extubation protocol. METHOD Patients wi...

متن کامل

The use of mechanical insufflation-exsufflation via artificial airways.

During the past 20 years, airway clearance techniques have been the subject of increasing scientific interest. Cough augmentation with mechanical insufflation-exsufflation is part of this trend. No fewer than 23 studies, of which 21 were published in the past 10 years, have improved the level of evidence on this technique.1-23 As suggested in Figure 1, the availability of insufflation-exsufflat...

متن کامل

Efficacy of mechanical insufflation-exsufflation in extubating unweanable subjects with restrictive pulmonary disorders.

BACKGROUND Subjects who do not pass ventilator weaning parameters but whose ambient air oxyhemoglobin saturation can be normalized by mechanical insufflation-exsufflation (MIE) can be extubated to continuous noninvasive ventilatory support (CNVS) with MIE used to maintain extubation. Our aim was to study MIE-associated changes in breathing tolerance, pulse oximetry, and vital capacity (VC) for ...

متن کامل

Noninvasive positive-pressure ventilation: a silver bullet for extubation failure?

Extubation failure, or the need for reintubation within 24–72 hours of extubation, occurs in up to 25% of critically ill patients. Extubation failure is associated with a markedly increased morbidity and mortality, including duration of mechanical ventilation, intensive care unit (ICU) and hospital stay, the need for post-acute-care hospitalization, and the need for tracheostomy.1,2 The most co...

متن کامل

Mechanical insufflation-exsufflation for airway mucus clearance.

Cough is an important component of airway clearance, particularly in individuals with intrinsic pulmonary disease, weakness of respiratory muscles, or central nervous system disease that impairs breathing. The use of assisted cough to enhance airway clearance in individuals with neuromuscular disease is essential to produce and maintain peak cough flow above a minimum and thereby avoid retained...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2012