Implant Materials Generate Different Peri-implant Inflammatory Factors

نویسندگان

  • Rene Olivares-Navarrete
  • Sharon L. Hyzy
  • Paul J. Slosar
  • Jennifer M. Schneider
  • Zvi Schwartz
  • Barbara D. Boyan
چکیده

STUDY DESIGN An in vitro study examining factors produced by human mesenchymal stem cells on spine implant materials. OBJECTIVE The aim of this study was to examine whether the inflammatory microenvironment generated by cells on titanium-aluminum-vanadium (Ti-alloy, TiAlV) surfaces is affected by surface microtexture and whether it differs from that generated on poly-ether-ether-ketone (PEEK). SUMMARY OF BACKGROUND DATA Histologically, implants fabricated from PEEK have a fibrous connective tissue surface interface whereas Ti-alloy implants demonstrate close approximation with surrounding bone. Ti-alloy surfaces with complex micron/submicron scale roughness promote osteoblastic differentiation and foster a specific cellular environment that favors bone formation whereas PEEK favors fibrous tissue formation. METHODS Human mesenchymal stem cells were cultured on tissue culture polystyrene, PEEK, smooth TiAlV, or macro-/micro-/nano-textured rough TiAlV (mmnTiAlV) disks. Osteoblastic differentiation and secreted inflammatory interleukins were assessed after 7 days. Fold changes in mRNAs for inflammation, necrosis, DNA damage, or apoptosis with respect to tissue culture polystyrene were measured by low-density polymerase chain reaction array. Data were analyzed by analysis of variance, followed by Bonferroni's correction of Student's t-test. RESULTS Cells on PEEK upregulated mRNAs for chemokine ligand-2, interleukin (IL) 1β, IL6, IL8, and tumor necrosis factor. Cells grown on the mmnTiAlV had an 8-fold reduction in mRNAs for toll-like receptor-4. Cells grown on mmnTiAlV had reduced levels of proinflammatory interleukins. Cells on PEEK had higher mRNAs for factors strongly associated with cell death/apoptosis, whereas cells on mmnTiAlV exhibited reduced cytokine factor levels. All results were significant (P < 0.05). CONCLUSION These results suggest that fibrous tissue around PEEK implants may be due to several factors: reduced osteoblastic differentiation of progenitor cells and production of an inflammatory environment that favors cell death via apoptosis and necrosis. Ti alloy surfaces with complex macro/micro/nanoscale roughness promote osteoblastic differentiation and foster a specific cellular environment that favors bone formation. LEVEL OF EVIDENCE N/A.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تعیین توزیع تنش استخوان اطراف ایمپلنت‌های فک پایین در طرح‎های مختلف پروتز به هنگام Mandibular- Flexure

Statement of Problem: In the treatment of edentulous patients with implant supported fixed partial dentures several factors such as implant numbers, implant position, superstructure pattern and cantilever length must be considered. Mandibular flexture in function exerts forces in peri-implant bone, however this phenomenon has received little attention. Purpose: The goal of this finite element a...

متن کامل

Biologic Width around Dental Implants: An Updated Review

Soft tissue-implant interface is an important anatomical feature contributing to the long-term success of dental implants. Based on the available evidence, different factors may influence biological width around implants including the surgical technique, implant loading, implant surface properties, abutment materials, implant position, and width of the peri-implant mucosa. The purpose of the pr...

متن کامل

Prevalence of Peri-implant Diseases associated with a Rough-Surface Dental Implant System: 9 Years after Insertion

Introduction: The aim of this study was a retrospective clinical evaluation of the long-term prevalence of peri-implant diseases associated with a modern rough-surface dental implant system. Materials and methods: A total of 237 implants were inserted in 47 patients between 1994 and 2005. Peri-implant parameters (sulcus bleeding, pocket depth and bone loss) were evaluated at a mean of 9.1 years...

متن کامل

Analysis of Potential Factors Affecting Peri-implant Sulcus Fluid (pisf) Volume

Background and Aim: PISF analysis is receiving more importance among site specific tests based on the understanding that it has the potential to reflect the actual status of periimplant soft and hard tissues. Better understanding of the biodynamics of peri-implant sulcular fluid (PISF) may be an important concern both from a clinical and research aspect. As peri-implant sulcular fluid volume is...

متن کامل

Maintenance of Dental Implants: A Review

  Objective: Successful bonding of a dental implant to bone, which was referred to as osseointegration by Branemark has been well documented. However, long-term prognosis of an implant depends on adequate maintenance and long-term care. An effective maintenance program is required to preserve the health of peri-implant tissues. Several techniques have been suggested for this purpose but it is n...

متن کامل

Assessment of Dentists’ knowledge of Peri-Implant Inflammatory Diseases and Their Related Treatment in Rasht

Introdouction: Implants are considered to be a useful treatment for the replacement of lost teeth. Although the success rate and durability of implants are high, the prevalence of peri-implantitis is high as well. The purpose of this study was to analyze the knowledge of general practitioners in the city of Rasht in Northern Iran regarding peri-implantitis and its treatment. Materials and meth...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 40  شماره 

صفحات  -

تاریخ انتشار 2015