The magnetic susceptibility effect of gadolinium-based contrast agents on PRFS-based MR thermometry during thermal interventions

نویسندگان

  • Nicole M Hijnen
  • Aaldert Elevelt
  • Jeroen Pikkemaat
  • Clemens Bos
  • Lambertus W Bartels
  • Holger Grüll
چکیده

BACKGROUND Proton resonance frequency shift (PRFS) magnetic resonance (MR) thermometry exploits the local magnetic field changes induced by the temperature dependence of the electron screening constant of water protons. Any other local magnetic field changes will therefore translate into incorrect temperature readings and need to be considered accordingly. Here, we investigated the susceptibility changes induced by the inflow and presence of a paramagnetic MR contrast agent and their implications on PRFS thermometry. METHODS Phantom measurements were performed to demonstrate the effect of sudden gadopentetate dimeglumine (Gd-DTPA) inflow on the phase shift measured using a PRFS thermometry sequence on a clinical 3 T magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) system. By proton nuclear magnetic resonance spectroscopy, the temperature dependence of the Gd-DTPA susceptibility was measured, as well as the effect of liposomal encapsulation and release on the bulk magnetic susceptibility of Gd-DTPA. In vivo studies were carried out to measure the temperature error induced in a rat hind leg muscle upon intravenous Gd-DTPA injection. RESULTS The phantom study showed a significant phase shift inside the phantom of 0.6 ± 0.2 radians (mean ± standard deviation) upon Gd-DTPA injection (1.0 mM, clinically relevant amount). A Gd-DTPA-induced magnetic susceptibility shift of ΔχGd-DTPA = 0.109 ppm/mM was measured in a cylinder parallel to the main magnetic field at 37°C. The temperature dependence of the susceptibility shift showed dΔχGd-DTPA/dT = -0.00038 ± 0.00008 ppm/mM/°C. No additional susceptibility effect was measured upon Gd release from paramagnetic liposomes. In vivo, intravenous Gd-DTPA injection resulted in a perceived temperature change of 2.0°C ± 0.1°C at the center of the hind leg muscle. CONCLUSIONS The use of a paramagnetic MR contrast agent prior to MR-HIFU treatment may influence the accuracy of the PRFS MR thermometry. Depending on the treatment workflow, Gd-induced temperature errors ranging between -4°C and +3°C can be expected. Longer waiting time between contrast agent injection and treatment, as well as shortening the ablation duration by increasing the sonication power, will minimize the Gd influence. Compensation for the phase changes induced by the changing Gd presence is difficult as the magnetic field changes are arising nonlocally in the surroundings of the susceptibility change.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MRgRFA: physical model and first order correction of PRFS thermometry corrupted by magnetic susceptibility-mediated cavitation’s effects

Introduction MR thermometry based on the proton resonance frequency (PRF) method (1) has gained good acceptance for guiding RF ablation of liver tumors (2). Major artifacts in the PRFS thermometry have recently been reported related to per-operatory changes of the tissue bulk susceptibility during RF heating (3). They are originating from gas bubbles formation, known as white cavitations’ artif...

متن کامل

Transurethral prostate thermotherapy: filtering the bowel motion during MR-thermometry processing

Background/introduction Magnetic resonance imaging (MRI)-guided transurethral ultrasound therapy is a minimally-invasive image-guided treatment for localized prostate cancer offering precise targeting of tissue within the gland. The accuracy of MR thermometry is critical for precise on-line feedback control as well as for monitoring potential thermal injury of surrounding tissues, especially th...

متن کامل

Feasibility of real-time MR thermal dose mapping for predicting radiofrequency ablation outcome in the myocardium in vivo

BACKGROUND Clinical treatment of cardiac arrhythmia by radiofrequency ablation (RFA) currently lacks quantitative and precise visualization of lesion formation in the myocardium during the procedure. This study aims at evaluating thermal dose (TD) imaging obtained from real-time magnetic resonance (MR) thermometry on the heart as a relevant indicator of the thermal lesion extent. METHODS MR t...

متن کامل

The feasibility of using arterial spin labeling for visualization of non perfused volumes after HIFU treatment in the kidney

Background/introduction MR guidance of High Intensity Focused Ultrasound (MFgHIFU) ablation offers the possibility to determine if complete tumor ablation has been established based on imaging the non-perfused volume (NPV). For thermal therapy, contrast enhanced (CE) imaging with a gadolinium-based contrast agent is currently the golden standard to quantify the NPV. A drawback of this method is...

متن کامل

Synthesis and biological evaluation of a novel Glucosylated Derivative of Gadolinium Diethylenetriaminepentaacetic acid for Tumor Magnetic Resonance Imaging

Cancer detection in early stage using a powerful and noninvasive tool is of high global interest. In this experiment, a small-molecular-weight glucose based derivative of Gd3+-1-(4-isothiocyanatobenzyl) diethylene tri amine penta acetic acid (Gd3+-p-SCN-Bn‐DTPA‐DG) as a novel potential MR imaging contrast agents was synthesized. Gd3+-p-SCN-Bn‐DTPA‐DG was synthesized with reacting of Glucosamine...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2013