Is it useful to increase dialysate flow rate to improve the delivered Kt?

نویسندگان

  • Marta Albalate
  • Rafael Pérez-García
  • Patricia de Sequera
  • Elena Corchete
  • Roberto Alcazar
  • Mayra Ortega
  • Marta Puerta
چکیده

BACKGROUND Increasing dialysate flow rates (Qd) from 500 to 800 ml/min has been recommended to increase dialysis efficiency. A few publications show that increasing Qd no longer led to an increase in mass transfer area coefficient (KoA) or Kt/V measurement. Our objectives were: 1) Studying the effect in Kt of using a Qd of 400, 500, 700 ml/min and autoflow (AF) with different modern dialysers. 2) Comparing the effect on Kt of water consumption vs. dialysis time to obtain an individual objective of Kt (Ktobj) adjusted to body surface. METHODS This is a prospective single-centre study with crossover design. Thirty-one patients were studied and six sessions with each Qd were performed. HD parameters were acquired directly from the monitor display: effective blood flow rate (Qbe), Qd, effective dialysis time (Te) and measured by conductivity monitoring, final Kt. RESULTS We studied a total of 637 sessions: 178 with 500 ml/min, 173 with 700 ml/min, 160 with AF and 126 with 400 ml/min. Kt rose a 4% comparing 400 with 500 ml/min, and 3% comparing 500 with 700 ml/min. Ktobj was reached in 82.4, 88.2, 88.2 and 94.1% of patients with 400, AF, 500 and 700 ml/min, respectively. We did not find statistical differences between dialysers. The difference between programmed time and Te was 8' when Qd was 400 and 500 ml/min and 8.8' with Qd = 700 ml/min. Calculating an average time loss of eight minutes/session, we can say that a patient loses 24' weekly, 312' monthly and 62.4 hours yearly. Identical Kt could be obtained with Qd of 400 and 500 ml/min, increasing dialysis time 9.1' and saving 20% of dialysate. CONCLUSIONS Our data suggest that increasing Qd over 400 ml/min for these dialysers offers a limited benefit. Increasing time is a better alternative with demonstrated benefits to the patient and also less water consumption.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dialysate flow rate and delivered Kt/Vurea for dialyzers with enhanced dialysate flow distribution.

BACKGROUND AND OBJECTIVES Previous in vitro and clinical studies showed that the urea mass transfer-area coefficient (K(o)A) increased with increasing dialysate flow rate. This observation led to increased dialysate flow rates in an attempt to maximize the delivered dose of dialysis (Kt/V(urea)). Recently, we showed that urea K(o)A was independent of dialysate flow rate in the range 500 to 800 ...

متن کامل

The patient as a limit to dialysis technology.

Ward et al. show in this issue of CJASN that Kt/V urea does not improve by increasing the dialysate flow rate in dialyzers in which dialysate flow distribution has been optimized by changes in design (1). Such improved dialyzer designs were developed during the last decade, based on the awareness that poor dialysate flow distribution and the occurrence of preferential dialysate flow paths negat...

متن کامل

Effect of cool dialysate on vital signs, comfort and adequacy

Abstract Introduction: Cool dialysate solution is an important factor in maintenance of cardio–vascular stability in hemodialysis patients. Objective: This study aimed to determine the effect of dialysate temperature on vital signs, comfort and adequacy of dialysis in hemodialysis patients. Methods: This study is a clinical trial conducted on 30 hemodialysis patients hospitalized in hemod...

متن کامل

In vivo effects of dialysate flow rate on Kt/V in maintenance hemodialysis patients.

It is generally assumed that hemodialysis adequacy is only minimally affected by increasing the dialysate flow rate (Qd). Recent in vitro studies showed that dialyzer urea clearance (Kd(urea)) may increase substantially more than expected in response to an increase in Qd. Because these studies implied that dialysis efficacy may benefit from greater Qds, we studied in vivo the effects of various...

متن کامل

Dialysis adequacy of chronic hemodialysis patients in Zanjan-Iran, 2016

Background: Dialysis adequacy is one of the most important factors in determining the survival rate and mortality of dialysis patients. Objectives: The aim of this study was to determine the dialysis adequacy of patients undergoing chronic hemodialysis at dialysis centers located in the province of Zanjan, located in northwest Iran. Methods: This descriptive cross-sectional study was performe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015