Association Between Ocular Surface Temperature and Tear Film Stability in Soft Contact Lens Wearers.

نویسندگان

  • Takashi Itokawa
  • Yukinobu Okajima
  • Takashi Suzuki
  • Koji Kakisu
  • Hiroko Iwashita
  • Yoshitaka Murakami
  • Yuichi Hori
چکیده

Purpose To investigate the correlation between the changes in the ocular surface temperature (OST) and tear film stability over soft contact lenses (SCLs). Methods We enrolled 20 eyes of 20 normal SCL wearers (20 men; 24.4 ± 4.1 years). We used four different daily disposable SCLs: one silicone hydrogel lens (delefilcon A) and three hydrogel lenses (etafilcon A with polyvinylpyrrolidone [PVP], etafilcon A, and polymacon). OST was measured every second during 10 seconds without blinking. We defined the difference in the OST from 0 to 10 seconds as ΔOST. To evaluate tear film stability, we measured noninvasive tear break-up time (NIBUT) and tear interference patterns on the contact lenses (TIPCL) using tear film interferometry. The parameters were measured before and 15 minutes after wearing each SCL. Results ΔOST was correlated significantly with NIBUT without (r = 0.411, P < 0.01) and with SCL (r = 0.642, P < 0.01). TIPCL grade was correlated significantly with ΔOST over SCLs (r = -0.636, P < 0.01). ΔOST was significantly smaller with silicone hydrogel delefilcon A than hydrogel etafilcon A and polymacon lenses (P < 0.05 and P < 0.01, respectively). Delefilcon A and etafilcon A with PVP lenses had significantly smaller NIBUT than etafilcon A (P < 0.05 for both comparisons). TIPCL grade of delefilcon A lens was significantly smaller than those of etafilcon A and polymacon (P < 0.01 for both comparisons). Conclusions The changes in OST over SCLs are related to tear film stability. Measurements of OST can be used to evaluate tear film stability for SCL wearers.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tear film, contact lens, and patient factors associated with corneal staining.

PURPOSE The purpose of this study was to examine ocular surface and tear film, contact lens, care solution, medical, and patient-related factors that are associated with corneal staining in contact lens wearers. METHODS In this cross-sectional/nested case-control study, in addition to the assessment of corneal staining with fluorescein, a variety of tear film and ocular surface, contact lens,...

متن کامل

Predicting success with silicone-hydrogel contact lenses in new wearers.

PURPOSE to evaluate changes in tear metrics and ocular signs induced by six months of silicone-hydrogel contact lens wear and the difference in baseline characteristics between those who successfully continued in contact lens wear compared to those that did not. METHODS Non-invasive Keratograph, Tearscope and fluorescein tear break-up times (TBUTs), tear meniscus height, bulbar and limbal hyp...

متن کامل

Tear Film Evaluation in Contact Lens Wearers and Non Wearers

Background: Dry eye symptoms are more frequent in contact lens wearers than in non wearers. Dry eye is considered relatively common in contact lens wearers than non-wearers. However, there was no any report in our clinical setting that compared and addressed the issue related to dry eye and its symptom in contact lens wearers. The present study was conducted to compare pre-ocular tear film in c...

متن کامل

Differences in clinical parameters and tear film of tolerant and intolerant contact lens wearers.

PURPOSE To determine whether intolerance to contact lens wear is attributable to clinical or protein characteristics of the tear film. METHODS Thirty-eight subjects participated; 20 were successful contact lens wearers and 18 had discontinued contact lens wear because of discomfort. Baseline tear film (no lens wear) was analyzed with a range of clinical measurements and protein analyses (lact...

متن کامل

Oral omega-6 essential fatty acid treatment in contact lens associated dry eye.

PURPOSE Symptoms of dry eye are commonly reported in contact lens wearers and are a frequent cause of non-tolerance. The purpose of the present study is to evaluate the effects of oral treatment with particular omega-6 fatty acids in the form of evening primrose oil (EPO) on subjective symptoms, ocular surface signs and tear film characteristic in patients with contact lens associated dry eye. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 59 2  شماره 

صفحات  -

تاریخ انتشار 2018