Agreement of noninvasive tear break-up time measurement between Tomey RT-7000 Auto Refractor-Keratometer and Oculus Keratograph 5M
نویسندگان
چکیده
BACKGROUND It is difficult to standardize assessment of dry eye in different clinical settings. Increasingly, tear stability is recognized to be important for the definition and assessment of patients with dry eye. Recently, two commercially available instruments have been made available for objectively measuring noninvasive tear break-up time (NIBUT), as an indicator of tear stability: the Tomey RT-7000 Auto Refractor-Keratometer and Oculus Keratograph (K)5M. We aim to assess the agreement of NIBUT measurements using these modalities. METHODS This prospective cross-sectional study was carried out in a tertiary referral eye center and involved 126 consecutive dry eye patients. NIBUT assessment was performed on the right eyes of participants with both the RT-7000 and the K5M techniques, with the order of assessment randomized. The Standardized Patient Evaluation of Eye Dryness (SPEED) questionnaires were administered to assess dry eye symptoms in the 2 weeks before assessment. RESULTS The age of the participants was 56.0±14.3 years (69.84% females). Measurements for both modalities were non-normally distributed (right-skewed). The median RT-7000 and K5M readings were 4.2 (range 0.1-10.0) and 6.4 (0.1-24.9) seconds, respectively. RT-7000 and K5M readings were poorly correlated (ρ=0.061, P=0.495). Intraclass correlation coefficient between the modalities was 0.187 (95% confidence interval -0.097 to 0.406). The Bland-Altman plot showed no systematic differences between the readings with these machines. The agreement between machines was not different in different SPEED categories. CONCLUSION While there are theoretical and practical benefits of NIBUT for assessment of tear stability over dye-based methods, the agreement between the two modalities was poor. Hence, studies and trials assessing NIBUT should avoid using these modalities interchangeably for NIBUT assessment. More research is needed to improve consensus on how to determine NIBUT.
منابع مشابه
Noninvasive assessment of tear stability with the tear stability analysis system in tear dysfunction patients.
PURPOSE To evaluate tear film stability in patients with tear dysfunction and an asymptomatic control group by using the novel, noninvasive Tear Stability Analysis System (TSAS). METHODS In this prospective case-control study, 45 patients with dysfunctional tear syndrome (DTS) were stratified into three groups (1, 2, and 3/4) based on clinical severity, with higher scores indicating more seve...
متن کاملEvaluation of Dry Eye and Meibomian Gland Dysfunction in Teenagers with Myopia through Noninvasive Keratograph
Purpose. This study aims to evaluate dry eye and ocular surface conditions of myopic teenagers by using questionnaire and clinical examinations. Methods. A total of 496 eyes from 248 myopic teenagers (7-18 years old) were studied. We administered Ocular Surface Disease Index (OSDI) questionnaire, slit-lamp examination, and Keratograph 5M. The patients were divided into 2 groups based on OSDI dr...
متن کاملInvestigation of the effects of Islamic fasting on ocular parameters
Purpose To investigate the effects of religious fasting during the month of Ramadan on intraocular pressure (IOP), refractive error, corneal tomography and biomechanics, ocular biometry, and tear film layer properties. Methods This prospective study was carried out one week before and in the last week of Ramadan. Ninety-four eyes of 94 healthy adult volunteers (54 males and 40 females) with a...
متن کاملRepeatability and Reproducibility of Noninvasive Keratograph 5M Measurements in Patients with Dry Eye Disease
Purpose. To determine the intraexaminer repeatability and interexaminer reproducibility of tear meniscus height (TMH) and noninvasive Keratograph tear breakup time (NIKBUT) measurements obtained with the Keratograph 5M (K5M) in a sample of healthy and dry eye populations. Methods. Forty-two patients with dry eye disease (DED group) and 42 healthy subjects (healthy group) were recruited in this ...
متن کاملComparison of keratometry and videokeratography after penetrating keratoplasty.
BACKGROUND As new methods for corneal curvature measurement have evolved, users of videokeratscopes need to know the practical limitations of these instruments. We assessed agreement between keratometry and videokeratography in measuring highly astigmatic corneas. METHODS Two independent examiners made three keratometric and videokeratographic measurements on each of 33 corneas after penetrat...
متن کامل