Analyses of trabecular bone failure

نویسنده

  • B. van Rietbergen
چکیده

Due to remodeling of bone architecture an optimal structure is created that minimizes bone mass and maximizes strength. In the case of osteoporotic vertebral bodies, however, this process can create over-adaptation, making them vulnerable for nonhabitual loads. In a recent study, micro-finite element models of a healthy and an osteoporotic human proximal femur were analyzed for the stance phase of gait. In the present study, tissue stresses and strains were calculated with the same proximal femur micro-finite element (micro-FE) models for a simulated fall to the side onto the greater trochanter. Our specific objectives were to determine the contribution of trabecular bone to the strength of the proximal femurs for this non-habitual load. Further, we tested the hypothesis that the trabecular structure of osteoporotic bone is over-adapted to habitual loads. For that purpose we calculated the load distributions and estimated the apparent yield and ultimate loads from linear analyses. Two different methods were used for this purpose, which resulted in very similar values, all in a realistic range. Distributions of maximal principal strain and effective strain in the entire model suggest that the contributions to bone strength of the trabecular and cortical structures are similar. However, a thick cortical shell is preferred over a dense trabecular core in the femoral neck. When the load applied to the osteoporotic femur was reduced to approximately 61 % of the original value, strain distributions were created similar in value to those obtained for the healthy femur. Since a comparable reduction factor was found for habitual load cases, it was concluded that the osteoporotic femur was not ‘over-adapted’.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation between lipid-lowering and bone-protective effects of eicosapentaenoic acid in rats with steroid-induced bone loss

This study was conducted to investigate the correlation between lipid-lowering and bone-protective effects of eicosapentaenoic acid on steroid-induced bonechanges in rats. Twenty-one male 10-week-old Wistar rats were divided into 3 groups (n = 7 each) and treated with 0.9% NaCl SC (group 1) or methylprednisolone 7 mg/kg SC once a week (group 2) or methylprednisolone 7 mg/kg SC once a week + eic...

متن کامل

Micromechanical analyses of vertebral trabecular bone based on individual trabeculae segmentation of plates and rods.

Trabecular plates play an important role in determining elastic moduli of trabecular bone. However, the relative contribution of trabecular plates and rods to strength behavior is still not clear. In this study, individual trabeculae segmentation (ITS) and nonlinear finite element (FE) analyses were used to evaluate the roles of trabecular types and orientations in the failure initiation and pr...

متن کامل

Mandibular Trabecular Bone Analysis Using Local Binary Pattern for Osteoporosis Diagnosis

Background: Osteoporosis is a systemic skeletal disease characterized by low bone mineral density (BMD) and micro-architectural deterioration of bone tissue, leading to bone fragility and increased fracture risk. Since Panoramic image is a feasible and relatively routine imaging technique in dentistry; it could provide an opportunistic chance for screening osteoporosis. In this regard, numerous...

متن کامل

Contribution of trabecular and cortical components to biomechanical behavior of human vertebrae: an ex vivo study.

Whereas there is clear evidence for a strong influence of bone quantity (i.e., bone mass or bone mineral density) on vertebral mechanical behavior, there are fewer data addressing the relative influence of cortical and trabecular bone microarchitecture. The aim of this study was to determine the relative contributions of bone mass, trabecular microarchitecture, and cortical thickness and curvat...

متن کامل

Analysis of Trabecular Bone Multiaxial Failure Using Large Scale Computation

INTRODUCTION Multiaxial failure behavior of trabecular bone is important clinically since multiaxial loads occur in vivo, and are associated with hip fractures [1, 2] and implant loosening [3]. Knowledge of the multiaxial failure behavior of trabecular bone also has biological importance since it will enable whole bone finite element models [4] to accurately predict failure loads. To date, no c...

متن کامل

Micro-finite element simulation of trabecular-bone post-yield behaviour--effects of material model, element size and type.

Micro-finite element (micro-FE) analysis became a standard tool for the evaluation of trabecular bone mechanical properties. The accuracy of micro-FE models for linear analyses is well established. However, the accuracy of recently developed nonlinear micro-FE models for simulations of trabecular bone failure is not known. In this study, a trabecular bone specimen was compressed beyond the appa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006