Exact Series Reconstruction in Photoacoustic Tomography with Circular Integrating Detectors

نویسندگان

  • Gerhard Zangerl
  • Otmar Scherzer
  • Markus Haltmeier
چکیده

A method for photoacoustic tomography is presented that uses circular integrals of the acoustic wave for the reconstruction of a three-dimensional image. Image reconstruction is a two-step process: In the first step data from a stack of circular integrating are used to reconstruct the circular projection of the source distribution. In the second step the inverse circular Radon transform is applied. In this article we establish inversion formulas for the first step, which involves an inverse problem for the axially symmetric wave equation. Numerical results are presented that show the validity and robustness of the resulting algorithm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Exact Reconstruction in Photoacoustic Tomography with Circular Integrating Detectors II: Spherical Geometry

Illuminating tissue with pulsed electromagnetic waves generates acoustic waves inside an object which can be measured and converted into a three dimensional (3d) image. This text is concerned with a twostep reconstruction method where the acoustic pressure is measured with circular integrating detectors. In the first step reconstruction formulas for some kind of projection of the source distrib...

متن کامل

Compensation of Ultrasound Attenuation in Photoacoustic Imaging

Photoacoustic imaging is a non-destructive method to obtain information about the distribution of optically absorbing structures inside a semitransparent medium. It is based on thermoelastic generation of ultrasonic waves by the absorption of a short laser pulse inside the sample. From the ultrasonic waves measured outside the object, the interior distribution of absorbed energy is reconstructe...

متن کامل

Improving tangential resolution with a modified delay-and-sum reconstruction algorithm in photoacoustic and thermoacoustic tomography.

Spatial resolution in photoacoustic and thermoacoustic tomography is ultrasound transducer (detector) bandwidth limited. For a circular scanning geometry the axial (radial) resolution is not affected by the detector aperture, but the tangential (lateral) resolution is highly dependent on the aperture size, and it is also spatially varying (depending on the location relative to the scanning cent...

متن کامل

Photoacoustic tomography with a limited-aperture planar sensor and a reverberant cavity

Biomedical photoacoustic tomography (PAT) is a soft-tissue imaging modality which combines the high spatial resolution of ultrasound (US) with the contrast and spectroscopic opportunities afforded by imaging optical absorption. Planar US arrays composed of piezoelectric or optical detector elements with small element sizes and fast acquisition times are readily available, making them an attract...

متن کامل

Fast Reconstruction Algorithms for the Thermoacoustic Tomography in Certain Domains with Cylindrical or Spherical Symmetries

We propose three fast algorithms for solving the inverse problem of the thermoacoustic tomography corresponding to certain acquisition geometries. Two of these methods are designed to process the measurements done with point-like detectors placed on a circle (in 2D) or a sphere (in 3D) surrounding the object of interest. The third inversion algorithm works with the data measured by the integrat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009