Innovative Methodology The respiratory change in preejection period: a new method to predict fluid responsiveness
نویسندگان
چکیده
Bendjelid, Karim, Peter M. Suter, and Jacques A. Romand. The respiratory change in preejection period: a new method to predict fluid responsiveness. J Appl Physiol 96: 337–342, 2004; 10.1152/ japplphysiol.00435.2003.—The accuracy and clinical utility of preload indexes as bedside indicators of fluid responsiveness in patients after cardiac surgery is controversial. This study evaluates whether respiratory changes ( ) in the preejection period (PEP; PEP) predict fluid responsiveness in mechanically ventilated patients. Sixteen postcoronary artery bypass surgery patients, deeply sedated under mechanical ventilation, were enrolled. PEP was defined as the time interval between the beginning of the Q wave on the electrocardiogram and the upstroke of the radial arterial pressure. PEP (%) was defined as the difference between expiratory and inspiratory PEP measured over one respiratory cycle. We also measured cardiac output, stroke volume index, right atrial pressure, pulmonary arterial occlusion pressure, respiratory change in pulse pressure, systolic pressure variation, and the down component of SPV. Data were measured without positive end-expiratory pressure (PEEP) and after application of a PEEP of 10 cmH2O (PEEP10). When PEEP10 induced a decrease of 15% in mean arterial pressure value, then measurements were re-performed before and after volume expansion. Volume loading was done in eight patients. Right atrial pressure and pulmonary arterial occlusion pressure before volume expansion did not correlate with the change in stroke volume index after the fluid challenge. Systolic pressure variation, PEP, down, and change in pulse pressure before volume expansion correlated with stroke volume index change after fluid challenge (r 0.52, 0.57, 0.68, and 0.83, respectively). In deeply sedated, mechanically ventilated patients after cardiac surgery, PEP, a new method, can be used to predict fluid responsiveness and hemodynamic response to PEEP10.
منابع مشابه
The respiratory change in preejection period: a new method to predict fluid responsiveness.
The accuracy and clinical utility of preload indexes as bedside indicators of fluid responsiveness in patients after cardiac surgery is controversial. This study evaluates whether respiratory changes (Delta) in the preejection period (PEP; DeltaPEP) predict fluid responsiveness in mechanically ventilated patients. Sixteen postcoronary artery bypass surgery patients, deeply sedated under mechani...
متن کاملThe following is the abstract of the article discussed in the subsequent
Bendjelid, Karim, Peter M. Suter, and Jacques A. Romand. The respiratory change in preejection period: a new method to predict fluid responsiveness. J Appl Physiol 96: 337–342, 2004; 10.1152/ japplphysiol.00435.2003.—The accuracy and clinical utility of preload indexes as bedside indicators of fluid responsiveness in patients after cardiac surgery is controversial. This study evaluates whether ...
متن کاملPleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre.
BACKGROUND Respiratory variations in pulse oximetry plethysmographic waveform amplitude (DeltaPOP) can predict fluid responsiveness in mechanically ventilated patients but cannot be easily assessed at the bedside. Pleth variability index (PVI) is a new algorithm allowing for automated and continuous monitoring of DeltaPOP. We hypothesized that PVI can predict fluid responsiveness in mechanicall...
متن کاملکتابخانه پستمدرن در عصر ارزیابی
Purpose: examining that the postmodern library as a fluid, ambiguous, and “quantum” organization how could be assessed. Methodology: conceptual analysis Findings: Today’s academic libraries face unprecedented challenges developed by the "dynamic of perpetual change". The present environment of unpredictable and perpetual change is not a phase or a period of transition but the new reality. In ...
متن کاملValue of systolic time intervals in the diagnosis of large patent ductus arteriosus in fluid-restricted and mechanically ventilated preterm infants.
M-mode echocardiographic features suggesting a patent ductus arteriosus are based on two groups of indirect criteria: dilation of the left cardiac cavities and changes of systolic time intervals. The reliability of the first group of criteria has been questioned in fluid-limited, mechanically ventilated preterm infants. The sensitivity of the systolic time intervals in the same circumstances is...
متن کامل