Factors concerned in the efficient steam sterilization of surgical dressings.

نویسنده

  • R J FALLON
چکیده

Some of the factors affecting the efficient steam sterilization of dressings have been examined. A jacketed sterilizer will process a load more quickly than a sterilizer without a jacket. The level of fore-vacuum is critical and must reach an absolute pressure of 20 mm. Hg (29.2 in.Hg vacuum) or less. This will overcome all conditions of overpacking studied. The level of after-vacuum should be 100 mm. Hg absolute or less, preferably near 50 mm. Hg absolute. Overpacking cannot be defined in terms of weight of a fabric per unit volume of container but occurs when a load is compressed in its container.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The sterilization of dressings.

The application of moist heat in an autoclave is the best method of sterilizing dressings. In order to kill the most resistant pathogenic spores they must be exposed for at least 20 minutes to saturated steam at 1210 C. (Ministry of Health, 1955). At this temperature pure steam exerts a pressure of 15 lb./sq. in. The steam should be dry but at the phase boundary between liquid and vapour, so th...

متن کامل

Monitoring sterilization of dressings in high-vacuum pressure-steam sterilizers.

Undetected air leaks in a high-vacuum sterilizer can defeat the sterilization process. For this reason the maintenance and supervision of these sterilizers needs expert engineering care. The importance of controlling the high-vacuum sterilization process from the centre of a load rather than the chamber drain is emphasized, and a method of detecting any failure in a high-vacuum process is descr...

متن کامل

بررسی اثر استریلیزاسیون خشک و مرطوب بر سایش لیگاچرکاترهای ارتودنتیک

Background and Aim: Orthodontic ligature cutting pliers are expensive. Methods of sterilization should be safe considering patients' health as well as lifetime of orthodontic pliers. The purpose of this study was to compare the wear of orthodontic ligature cutting pliers after sterilizing with dry heat or steam autoclave. Materials and Methods: In this experimental study, thirty ligature cuttin...

متن کامل

Observance of Infection Control and Sterilization Standards in Limited Surgical Centers of Tehran University of Medical Sciences

Observance of Infection Control and Sterilization Standards in Limited Surgical Centers of Tehran University of Medical Sciences Mojgan Dadashi1*, Afsaneh Sheikh-Sofla2, Sadaf Alipour3, Mohamad-Reza Cheragh-zadeh4, Nasrin Abbasi5 1M.Sc. in Midwifery, MPH Reproductive Health, Expert on the Supervision of Treatment, Treatment Department, Tehran University of Medical Sciences, Tehran, Iran 2M.Sc...

متن کامل

Monitoring steam sterilization of surgical instruments: a dilemma.

The study of two biological indicators in monitoring "flash" sterilization demonstrated that indicator construction often leads to a false interpretation of spore survival.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 14  شماره 

صفحات  -

تاریخ انتشار 1961