A recording tonometer.

نویسنده

  • D M MAURICE
چکیده

THE measurement of the resistance to outflow of the aqueous humour by the procedure of tonography has recently aroused interest in the continuous recording of the intra-ocular pressure (IOP). There are, in addition, numerous other physiological and clinical investigations which could be performed if it were possible to obtain a continuous and accurate record of the IOP in human subjects. Such recordings have been obtained using the Muller electronic tonometer connected to a suitable amplifier and recording galvanometer. This arrangement, however, suffers from several disadvantages. First, the tonometer must be held continuously on the patient's eye by an operator, and this limits the time during which the record can be continuously taken. An improvement may be effected by using a mechanical holder, such as that designed by Merte (1957), but some supervision would still be required. Secondly, the fact that it is impossible for the patient to move his head makes many experimental procedures impossible. Thirdly, the Muller instrument, being basically a Schi6tz tonometer, suffers from the defects of this instrument, principally that its application to the eye raises its IOP to about double its original value (Friedenwald, 1954), the extent of the rise varying from eye to eye in a not readily determinable manner. The instrument described in this paper is essentially a research tool and is too complicated for widespread use as a routine clinical instrument. It was designed to be mounted on the patient's forehead and to maintain its position on the eye without attention and regardless of the position of the patient's head. In addition, it seems to be intrinsically more accurate than the Schiotz tonometer. The theoretical principle on which it operates and its practical construction are first explained, and further sections describe its method of use and its performance. Only the results of investigations into normal eyes are reported in this paper; it is intended to publish studies on glaucomatous patients later. Finally, an account of the calibration of the tonometer on human cadavers is given, from which the value of the normal IOP is derived.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Postural change and intraocular pressure in glaucomatous eyes.

Several authors (Anderson and Grant, I973; Galin, Mclvor, and Magruder, I963; HetlandEriksen, I966; Kriegelstein and Langham, 1975a; Roberts and Rogers, I964; Tarkkanen and Leikola, I967) have reported that in normal subjects and in glaucomatous patients the intraocular pressure (IOP) in the supine position is about 2-5 mmHg higher than in the seated position. The measurements were carried out ...

متن کامل

Selected parameters of the corneal deformation in the Corvis tonometer

INTRODUCTION Contemporary ophthalmology knows many methods of measuring intraocular pressure, namely the methods of non-contact and impression applanation tonometry. In non-contact applanation tonometers, e.g. the Corvis, the corneal flattening is caused by an air puff. Image registration of the corneal deflection performed by a tonometer enables to determine other interesting biomechanical par...

متن کامل

The ocular pulse and intraocular pressure as a screening test for carotid artery stenosis.

The ocular pulse and applanation tension were measured with a recording applanation tonometer in 38 patients suspected of having internal carotid artery stenosis. Abnormalities of the ocular pulse amplitude, intraocular pressure, or combinations of these two measurements were found in 23 (82%) of 28 patients who were subsequently found to have angiographic evidence of 50% or more stenosis of on...

متن کامل

Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry

BACKGROUND The new Ocular Dynamic Contour Tonometer (DCT), investigational device supplied by SMT (Swiss Microtechnology AG, Switzerland) allows simultaneous recording of intraocular pressure (IOP) and ocular pulse amplitude (OPA). It was the aim of this study to compare the IOP results of this new device with Goldmann tonometry. Furthermore, IOP and OPA measured with the new slitlamp-mounted D...

متن کامل

Diagnostic accuracy of the iCare rebound tonometer compared to the Perkins applanation tonometer in assessing intraocular pressure in rural patients.

BACKGROUND Vision health is recognized as a critical unmet need in North America. The ocular morbidity associated with glaucoma results from increased intraocular pressure (IOP) and early detection is crucial for the management of glaucoma. Our objective was to find a diagnostically accurate screening tool for intraocular hypertension that can be used in rural communities. We sought to validate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 42 6  شماره 

صفحات  -

تاریخ انتشار 1958