[Placement of a shape-memory alloy intraurethral catheter (Memokath) using transrectal ultrasonography and fluoroscopy].
نویسندگان
چکیده
Intraurethral catheters are effective in the treatment of elderly patients with benign prostate hyperplasia (BPH) who have severe complications. However, it is not easy to measure the length of the prostatic urethra and to determine an appropriate location for the urethral catheter using only fluoroscopy, especially in patient with severe mid-lobe enlargement. We attempted to place a shape-memory alloy intraurethral catheter (MEMOKATH) by transrectal ultrasonography and fluoroscopy to measure the precise length of the prostatic urethra and to determine an appropriate location for an intraurethral catheter placement. Patients were given urethral infiltration anesthesia with 2% lidocaine hydrochloride jelly and placed in the supine position. Both transrectal ultrasonography and fluoroscopy were performed to observe the bladder neck, the apex of the prostate gland, and the prostatic urethra. Transrectal ultrasonography was shown to depict them more clearly than fluoroscopy. Transrectal ultrasonography was also shown to be more suitable than fluoroscopy for measuring the prostatic urethra length, as well as for accurately positioning the MEMOKATH stent, especially in cases of BPH with mid-lobe enlargement. The MEMOKATH stent was placed in 7 patients with BPH. Urethral catheters had been put in place in 6 of these patients because of urinary retention, and large amounts of residual urine were found in the remaining patient. Three patients had severe mid-lobe enlargement. All patients were able to urinate without much residual urine after the procedure. No severe complications were noted. Transrectal ultrasonography is useful for accurately placing the MEMOKATH stent, as it provides more objective and detailed anatomical findings than fluoroscopy.
منابع مشابه
Palliation of terminal malignancy with shape memory alloy ureteric stents.
We report on the first case in Ireland of ureteric stenting with shape-memory alloy nickel-titanium (Memokath 051) stent in relieving malignant ureteric obstruction. Successful drainage was achieved and the patient required no further intervention indicating a clear place for these stents in the long-term management of malignant ureteric strictures. The use of ureteric double-J stenting in the ...
متن کاملFabrication of Spiral Stent with Superelastic/ Shape Memory Nitinol Alloy for Femoral Vessel
Stent is a metal mesh tube for opening the obstructed vessels of the body. Ni-Ti alloy is a suitable metal for fabrication of stent due to its potential for applying the appropriate stress and strain to the vessel walls. In this study, super-elastic Nitinol wire was used to build stent samples usable to open femoral vessel. Ageing was performed at 500°C for different periods of time to determin...
متن کاملAdaptive Tunable Vibration Absorber using Shape Memory Alloy
This study presents a new approach to control the nonlinear dynamics of an adaptive absorber using shape memory alloy (SMA) element. Shape memory alloys are classified as smart materials that can remember their original shape after deformation. Stress and temperature-induced phase transformations are two typical behaviors of shape memory alloys. Changing the stiffness associated with phase tran...
متن کاملSEISMIC OPTIMIZATION OF STEEL SHEAR WALL USING SHAPE MEMORY ALLOY
Nowadays, steel shear walls are used as efficient lateral-load-resistant systems due to their high lateral stiffness and carrying capacity. In this paper, the effect of substituting a shape memory alloy (SMA) material is investigated instead of using conventional steel in the shear wall. A numerical study is conducted using finite element method (FEM) by OpenSees software. For this purpose, at ...
متن کاملNonlinear Thermo-Mechanical Behaviour Analysis of Activated Composites With Shape Memory Alloy Fibres
General thermo-mechanical behavior of composites reinforced by shape memory alloy fibers is predicted using a three-dimensional analytical micromechanical method to consider the effect of fibers activation. Composite due to the micromechanical method can be exposed to general normal and shear mechanical and thermal loading which cause to activate the shape memory alloy fibers within polymeric m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nihon Hinyokika Gakkai zasshi. The japanese journal of urology
دوره 100 3 شماره
صفحات -
تاریخ انتشار 2009