Real time magnetic resonance assessment of septal curvature accurately tracks acute hemodynamic changes in pediatric pulmonary hypertension

نویسندگان

  • Bejal Pandya
  • Michael A Quail
  • Jennifer Steeden
  • Andrew Taylor
  • Ingram Schulze-Neick
  • Graham Derrick
  • Shahin Moledina
  • Vivek Muthurangu
چکیده

BACKGROUND This study assesses the relationship between septal curvature and mean pulmonary artery pressure and indexed pulmonary vascular resistance in children with pulmonary hypertension. We hypothesized that septal curvature could be used to estimate right ventricular afterload and track acute changes in pulmonary hemodynamics. METHODS AND RESULTS Fifty patients with a median age of 6.7 years (range, 0.45-16.5 years) underwent combined cardiac catheterization and cardiovascular magnetic resonance. The majority had idiopathic pulmonary arterial hypertension (n=30); the remaining patients had pulmonary hypertension associated with repaired congenital heart disease (n=17) or lung disease (n=3). Mean pulmonary artery pressure and pulmonary vascular resistance were acquired at baseline and during vasodilation. Septal curvature was measured using real-time cardiovascular magnetic resonance. There was a strong correlation between mean pulmonary artery pressure and SCmin at baseline and during vasodilator testing (r=-0.81 and -0.85, respectively; P<0.01). A strong linear relationship also existed between pulmonary vascular resistance and minimum septal curvature indexed to cardiac output both at baseline and during vasodilator testing (r=-0.88 and -0.87, respectively; P<0.01). Change in septal curvature metrics moderately correlated with absolute change in mean pulmonary artery pressure and pulmonary vascular resistance, respectively (r=0.58 and -0.74; P<0.01). Septal curvature metrics were able to identify vasoresponders with a sensitivity of 83% (95% confidence interval, 0.36-0.99) and a specificity of 91% (95% confidence interval, 0.77-0.97), using the Sitbon criteria. Idiopathic pulmonary arterial hypertension subgroup analysis revealed 3 responders with ΔSCmin values of 0.523, 0.551, and 0.568. If the middle value of 0.551 is taken as a cutoff, the approximate sensitivity would be 67% and the specificity would be 93%. CONCLUSIONS Septal curvature metrics are able to estimate right ventricular afterload and track acute changes in pulmonary hemodynamics during vasodilator testing. This suggests that septal curvature could be used for continuing assessment of load in pulmonary hypertension.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Cardiovascular magnetic resonance evaluation of left-to-right shunts due to cardiac septal defects in patients with pulmonary arterial hypertension].

INTRODUCTION AND OBJECTIVES As cardiac septal defects are frequently associated with pulmonary arterial hypertension, hemodynamic assessment is essential before deciding on surgery. The aim of this study was to evaluate the use of cardiovascular magnetic resonance imaging for assessing cardiac shunts and for quantifying pulmonary artery systolic pressure in patients with cardiac septal defects....

متن کامل

Right ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease

Introduction:  In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...

متن کامل

Role of cardiac magnetic resonance imaging in the management of patients with pulmonary arterial hypertension.

Pulmonary arterial hypertension (PAH) is a progressive disorder characterized by abnormally elevated blood pressure of the pulmonary circulation that results, over time, from extensive vascular remodeling and increased pulmonary vascular resistance. Recent advances in magnetic resonance imaging (MRI) technology have led to the development of techniques for noninvasive assessment of cardiovascul...

متن کامل

The duration of interventricular septal displacement in patients with precapillary pulmonary hypertension as a potential marker of right ventricular dysfunction and pressure overload. A cardiac magnetic resonance study

Background Right ventricular (RV) pressure overload results in interventricular septal displacement (IVSD) towards left ventricle in patients with pulmonary arterial hypertension (PAH). There is however scarce data on the duration of IVSD during cardiac cycle as expressed by curvature duration index (CDi) and its potential role in the evaluation of PAH patients. The aim of our study is to revea...

متن کامل

Noninvasive monitoring of serial changes in pulmonary vascular resistance and acute vasodilator testing using cardiac magnetic resonance.

OBJECTIVES The study sought to evaluate the ability of cardiac magnetic resonance (CMR) to monitor acute and long-term changes in pulmonary vascular resistance (PVR) noninvasively. BACKGROUND PVR monitoring during the follow-up of patients with pulmonary hypertension (PH) and the response to vasodilator testing require invasive right heart catheterization. METHODS An experimental study in p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2014