New echocardiographic imaging method based on the bandwidth of the ultrasound Doppler signal with applications in blood/tissue segmentation in the left ventricle

نویسندگان

  • Sigve Hovda
  • Håvard Rue
  • Bjørn Olstad
چکیده

A new imaging method, Bandwidth Imaging, which is related to the bandwidth of the ultrasound Doppler signal is proposed as a classification function for blood and tissue signal in transthoracial echocardiography in the left ventricle. An in vivo experiment is presented, where the apparent error rate of Bandwidth Imaging is compared with the apparent error rate of Second-Harmonic Imaging on 15 healthy men. The apparent error rates are calculated from the 16 myocardial wall segments defined in [M.D., Cerqueira, N.J. Weissman, V. Dilsizian, A.K. Jacobs, S. Kaul, W.K. Laskey, D.J. Pennell, J.A. Rumberger, T. Ryan, M.S. Verani, Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart, Circulation (2002) 539-542]. A hypothesis test of Bandwidth Imaging having lower apparent error rate than Second-Harmonic Imaging is proved for a p-value of 0.94 in three segments in end diastole and in one segment in end systole. When data was averaged by a structural element of five radial, three lateral and four temporal samples the numbers of segments increased to nine in end diastole and to six in end systole. This experiment indicates that Bandwidth Imaging can supply additional information for automatic border detection routines on endocardium.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Echocardiographic Assessment of Left Ventricle Torsion by Tissue Doppler and Velocity Vector Imaging

Introduction Left ventricular (LV) twist is believed to store potential energy and plays an important role in generating diastolic suction. Recent advances in echocardiography techniques have allowed quantification of LV twist. The aim of the present study was to compare LV twist and torsion in healthy human subjects determined by velocity vector imaging (VVI) and tissue Doppler imaging (TDI) a...

متن کامل

Bandwidth of the Ultrasound Doppler Signal with Applications in Blood/Tissue Segmentation in the Left Ventricle

A new estimator, Bandwidth Imaging, related to the bandwidth of the ultrasound Doppler signal is proposed as a classification function of blood and tissue signal in transthoracial echocardiography of the left ventricle. An in vivo experiment is presented, where the apparent error rate of Bandwidth Imaging is compared with the apparent error rate of Second-Harmonic Imaging on 15 healthy men. The...

متن کامل

Non-invasive estimation of cardiac wall stress by using tissue doppler-echocardiography ultrasound images: People with coronary artery stenosis

In this study, a method for non-invasive estimation of stress on the heart wall in  the diastole phase is presented using ultrasound echocardiography and tissue Doppler  imaging. The aim of this study was to evaluate the stress on the heart wall as a  pre-diagnosis  to identify people with coronary artery stenosis. 29 patients with stenosis of more than 70%, 30 patients with stenosis of 50 to 7...

متن کامل

Cardiac Involvement in Mild Cystic Fibrosis Lung Involvement Assessed by Tissue‐Doppler Echocardiography

Background:Cystic Fibrosis (CF) is a systemic disease affecting extra pulmonary dysfunction as a result of CF-related lung disease. Because of lack of enough studies in this field and utilization of TDE in this field, we aimed to evaluate t...

متن کامل

A Semi-Automated Algorithm for Segmentation of the Left Atrial Appendage Landing Zone: Application in Left Atrial Appendage Occlusion Procedures

Background: Mechanical occlusion of the Left atrial appendage (LAA) using a purpose-built device has emerged as an effective prophylactic treatment in patients with atrial fibrillation at risk of stroke and a contraindication for anticoagulation. A crucial step in procedural planning is the choice of the device size. This is currently based on the manual analysis of the “Device Landing Zone” fr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Computer methods and programs in biomedicine

دوره 92 3  شماره 

صفحات  -

تاریخ انتشار 2008