Verification of Optical Fiber and Cable Reliability

نویسنده

  • Kevin Houser
چکیده

As environments are becoming increasingly harsh, the ability of optical fiber cable to withstand such environments is of the utmost importance to outside plant users. Laboratory accelerated aging environments have long been used as a measure to predict field performance of optical fiber and cables' ability to withstand harsh environments. However, there has been an issue in linking the laboratory environments with actual field exposure. To this end, actual field data from such a cable should provide real evidence of an optical fiber cable's ability to withstand these environments, thus providing the link between actual long-term reliability and laboratory tests. In the present study, a 10 year-old field-aged cable was extracted from its deployed environment and tested to determine its resilience in withstanding mechanical and environmental conditions. In order to assess its resilience, a wide range of tests was performed on the aged cable and its components. The results of these tests were compared to test results obtained from unaged samples of the same era as well current data on the same design. Surface roughness of the fiber was determined using an Atomic Force Microscope (AFM). Strength testing was conducted to verify failure probability. In addition, fiber strip force testing and Fourier Transform InfraRed (FTIR) analysis were conducted to determine the effect of aging on the coating materials. Optical and material performances of the cable under mechanical stress were compared to historical test data on the single-armored, sixposition, loose-tube cable design. These tests were performed in accordance to industry standard requirements. Testing results showed that there exists no significant degradation in the optical fiber cable's performance, which verifies laboratory testing and speaks to the true reliability of optical fiber cable. Cable Design and History The design is a single-armored, six-position cable (see Figure 1) which contains two live gel-filled 2.5/1.5 mm tubes with six fibers each, three soft fillers and one hard filler. The cable was manufactured in 1987 in compliance with Bellcore Specifications TR-TSY-000020, Issue 3 requirements. The fiber is Corning SMF-28 CPC3 standard single-mode optical fiber. In 1987, the cable was installed in Oregon, at the base of the Cascade Mountain foothills, between the town of Medford and the Rogue River. The geography of the installation site indicates that it is a river valley surrounded by four mountain ranges. East of Medford are the Cascade Mountains with an elevation of 4,000(1219.5m) to 9,500 feet(2896m) and west of Medford are the Coast Range Mountains with an elevation of 3,500(921.1m) to 5,500 feet(1676.8m). North of Medford is the Umpqua Divide with elevations from 3,500(921.1m) to 5,500 feet(1676.8m) and south of Medford are the Siskiyous Mountains with elevations from 3,000(914.6m) to 7,600 feet(2317m). The approximate mean annual temperature for Medford is 53°F(11.7°C) with recorded low temperatures of 0°F(-17°C) and high temperatures of 100°F(37°C). The mean annual precipitation averages 20.6-in(52.4 cm.) and average annual snowfall is 8.1 in (20.6cm). Because of it’s geographical location, Medford is subjected to annual flooding and mudslides. A mudslide in 1997 was responsible for 200 feet (61m) of this cable surfacing in a washout. The customer decided to reroute and replace the cable since the vicinity of a mudslide remains unstable for long periods. After rerouting the new cable, 86 feet of the 1987 cable was removed from a manhole and sent back to Pirelli Cable and Systems North America research facility for evaluation. The 10-year-old field aged cable was an opportunity to benchmark and compare some of the mechanical, material and optical performances of a field-aged cable with original test results recorded on this 1987 cable design. Figure 1. Loose-Tube Cable Structure

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

40 Gbps / 100 Gbps Large - Capacity Optical Transmission Equipment

1. Introduction In order to meet the rapidly increasing demand for communications over metro networks and international submarine cable networks, it is essential to secure larger transmission capacity and higher equipment reliability. Indispensable technologies to satisfy these requirements include: design and verification technologies that realize large-capacity transmission of 40 and 100 Gbps...

متن کامل

Submarine Optical Cables as a Key Component in Undersea Telecommunications: A Review

Undersea fiber optic cables make the web worldwide. The main advantage of underwater optical fiber communication is the reliability of under cables. It is high due to extended repeater spacing. Submarine optical cable is the key component of the undersea optical system. Present paper discusses the various aspects of undersea optical telecommunications.

متن کامل

Fiber Optic Cable Assemblies for Space Flight Applications III: Characterization of Commercial Cables for Thermal Effects

Introduction This is the third paper in a series of white papers addressing the issues associated with the usage of optical fiber cables in space flight applications.[1-2] These experiments to characterize commercially available optical fiber cables are crucial to deciding which cables are appropriate for which space flight mission based on their environmental performance. The objective of this...

متن کامل

The Reliability Evaluation Method Study of Power System Communication Networks in Case of Ice Storm

This paper is divided into two cases to study the communication transmission equipment reliability in the state of the ice storm, according to the huge losses of power system communication caused by the ice storm. For the nodes or links which are not affected by the ice storm, we use the calculation with “the mean time between failures (MTBF)” and “the mean time to repair” (MTTR) to put forward...

متن کامل

Optical Transmission System for High Field Systems

Introduction: Interconnection problems between large number of coil elements and the scanner are critical, particularly in high field MRI. Moreover, SNR and RF safety issues are also significant concerns. Recent investigations on the analog optical transmission of MRI signals may alleviate this problem [1-3]. Although traditionally, the transmission of the MR signals is achieved by coaxial cabl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999